PING WATCHDOG
You must enter an address to which the DB2003 must send a ping at certain intervals. When the
set number of unsuccessful attempts is reached, the selected GPO is activated. A GPO is generally of
the pulse type and cuts the power supply to the controlled device, causing a reboot.
Startup Delay
sets the time for the controlled device to reboot, during which no ping is sent.
With the [Test] button, users can check the routing to the specified address.
DEVICE MANAGEMENT
Reboot Device
[Reboot Device] causes the device (DB2003) to re-start. It does not change the settings or delete
the logs. If Dayparting has been activated for any Telemetry Port, a command will be sent to the
monitored device to determine the forward power in accordance with the current time.
Restore All Except IP
[Restore All Except IP] causes all settings to be restored to their default values. It does not affect
the IP address settings, so it is still possible to connect to the device. The Timezone setting is not
changed. Logs are not deleted.
No commands are sent to the monitored devices. All Telemetry Ports are disabled, selected models
and parameters for connecting to the monitored devices are canceled.
RECOMMENDATION
: Prior to taking this action, make sure you have all the data required for
restoring the connection to the monitored devices – interface, speed, address, model, etc.