Rev 07/04/2015
32
4.3. ACCESSING THE CONDENSING UNIT
4.3.1 Unit from 5 to 18 shelves
a) Remove the rear grid by unscrewing corner screws.
b) Remove the front panel and unscrew the left and right side bolts from the
compressor base plate at the sides of the condenser.
c) Disconnect the keypad wires and loosen or cut the cable ties to extend the length to
make clearance to slide out the compressor base.
d) Cut the ties which hold the drain duct