Repair Work Safety
WARNING Repair work must only be performed by Desmon’s approved
distributors or one of its authorized representatives. Desmon accepts no
responsibility for any situation resulting from work performed by untrained and/or
unauthorized technicians.
ELECTRICAL LOCKOUT/TAGOUT PROCEDURE
WARNING Before performing any service that involves electrical connection or
disconnection and/or exposure to electrical components, always follow the
Electrical LOCKOUT/TAGOUT Procedure. Disconnect all circuits. Failure to comply
can cause property damage, injury or death.
The Electrical LOCKOUT/TAGOUT Procedure is used to protect personnel working
on an electrical appliance. Before performing any maintenance or service that
requires exposure to electrical components, follow these steps:
1. In electrical box, place appliance circuit breaker into OFF position.
2. Place a lock or other device on electrical box cover to prevent someone from
placing circuit breaker ON.
3. Place a tag on electrical box cover to indicate that appliance has been
disconnected for service and power should not be restored until tag is removed by
maintenance personnel.
4. Disconnect appliance power cord from electrical outlet.
5. Place a tag on the cord to indicate that unit has been disconnected for service
and power should not be restored until tag is removed by maintenance personnel.
Summary of Contents for GBC-15
Page 1: ...Service Manual Blast Chiller...
Page 2: ...Rev 07 04 2015 2...
Page 3: ...Blast chiller Service Manual 3 Rev 07 04 2015...
Page 32: ...Rev 07 04 2015 32...
Page 40: ...Rev 07 04 2015 40...
Page 50: ...Rev 07 04 2015 10 20 10 0 10 20 30 40 kOhms C kOhmsVsTempChart NTC 10kOhms 25 C ZOOM...
Page 57: ...Blast chiller Service Manual 17 Rev 07 04 2015 L1 L2...
Page 91: ...Blast chiller Service Manual 51 Rev 07 04 2015 6 SCHEMATICS 6 1 SCHEME OF COMPONENTS...
Page 97: ...Blast chiller Service Manual 57 Rev 07 04 2015...
Page 100: ...Rev 07 04 2015 60...