SETTING THE DOUBLE THERMOSTAT
The heater is supplied with the double thermostat already adjusted according to the following table:
FAN Function
25 – 35°C
LIMIT Function
100°C
If you need to check or re-adjust the thermostat operation settings, observe the following notes.
Legend:
1. White push-button for Automatic-Manual ventilation (if
present).
2. Electric connections for FAN function.
3. Graduated scale.
4. Holes for fastening.
5. Fan unit stop temperature indicator.
6. Temperature indicator for LIMIT safety actuation.
7. Slots for cable fastening. Pushing a screwdriver blade
in this slot opens the terminal so that the cable can be
inserted. On removing the screwdriver blade, the cable
is automatically fastened in the terminal.
ATTENTION
Make sure the cable is tight in the terminal
by pulling slightly.
8. Temperature indicator for fan unit starting.
9. Electrical connections for LIMIT safety function.
10. Red push-button to reset after safety lockout (where
present).
11. Metal bridge (where present).
ATTENTION
On models
type 1
÷
4
the metal bridge
11
must be
present.
On models from
type 5
to
type 7
the metal bridge
11
must be removed.
Type 1÷4
Type 5÷7
15
Summary of Contents for BG 110
Page 30: ...PROSTOR PRO PŘÍPADNÉ POZNÁMKY 30 ...
Page 94: ...ESPACIO PARA EVENTUALES NOTAS 30 ...
Page 158: ...3 NOTES 30 ...
Page 190: ...2 SPAZIO PER EVENTUALI NOTE 29 30 ...
Page 222: ...MIEJSCE NA EWENTUALNE UWAGI 30 ...
Page 256: ...ПРИМЕЧАНИЯ 32 ...