![Denyo DCA-150LSKE Instruction Manual Download Page 65](http://html1.mh-extra.com/html/denyo/dca-150lske/dca-150lske_instruction-manual_2485063065.webp)
- 61 -
8-2
Connection
of
booster
cable,
and
installation
When
the
engine
is
started
using
booster
cables,
connect
the
cables
as
follows.
(1)
Connection
of
booster
cable
①
Connect
the
clip
of
the
booster
cable
"A"
to
the
terminal
"+"
of
the
machine
in
trouble.
②
Connect
the
other
clip
of
the
booster
cable
"A"
to
the
terminal
"+"
of
normal
machine.
③
Connect
the
clip
of
the
booster
cable
"B"
to
the
terminal
"B"
to
the
terminal
"-"
of
normal
machine.
④
Connect
the
other
clip
of
the
booster
cable
"B"
to
the
engine
block
of
the
machine
in
trouble.
(2)
Removal
of
booster
cable
①
Remove
the
clip
of
the
booster
cable "B"
connected
to
the
engine
block
of
the
machine
in
trouble.
②
Remove
the
clip
of
the
booster
cable
"B"
connected
to
the
terminal
"-"
of
normal
machine.
③
Remove
the
clip
of
the
booster
cable
"A"
connected
to
the
terminal
"+"
of
normal
machine.
④
Remove
the
clip
of
the
booster
cable
"A"
connected
to
the
terminal
"+"
of
the
machine
in
trouble.
(3)
Caution
on
handling
of
booster
cable
①
Use
booster
cables
and
clips
of
the
size
that
matches
the
size
of
battery.
②
The
battery
used
for
normal
machine
should
be
the
same
in
capacity
as
the
battery
of
the
machine
in
trouble.
③
After
connection,
check
that
clips
are
firmly
connected.
④
When
connecting
booster
cables,
make
sure
that
the
terminal
"+"
does
not
touch
the
terminal
"-".
⑤
The
engine
block
should
be
connected
at
a
place
more
than
30cm
away
from
the
battery.
Summary of Contents for DCA-150LSKE
Page 2: ...Japan...
Page 18: ...14 16 environmental base fluid level warning lamp...
Page 55: ...51 When the single parallel change over switch is parallel side device acts...
Page 93: ...89 12 2 Outline drawing...
Page 94: ...90 12 3 Generator connection diagram...
Page 95: ...91 12 4 Engine wiring diagram...
Page 96: ...92 12 5 Controller wiring diagram...
Page 101: ...97...