![Denyo DCA-150LSKE Instruction Manual Download Page 21](http://html1.mh-extra.com/html/denyo/dca-150lske/dca-150lske_instruction-manual_2485063021.webp)
- 17 -
(3) Alarm and Memory at Abnormal Condition
When any abnormal condition occurs in engine oil pressure, battery charging voltage,
or engine coolant temperature, the indication will change as the following ;
- 1 - The Indicator shows its defect with blinking numbers.
- 2 - When the abnormal condition is corrected, the on - and - off indication will stop.
- 3 - If engine would stop urgently and automatically or stop manually with the abnormal
condition, the abnormal value will be memorized, and then indicated even after engine
is started again.
In this case, keep on pushing the button "RESET" for more than 5 seconds, and the
abnormal indication will be reset to normal.
(4) Hour Meter
①
When you turn the starter switch to "RUN" position, and push the selector button
located on the right side of the Hour Meter, you can see the numbers mentioned
below ;
・
"ODO" Total running hour
・
"TRIP A " Running hours "A" on a certain period
・
"TRIP B " Running hours "B" on a certain period
②
If you want to reset the Trip Meters, push the selector button for more than 1 second,
after selecting each meters.
Summary of Contents for DCA-150LSKE
Page 2: ...Japan...
Page 18: ...14 16 environmental base fluid level warning lamp...
Page 55: ...51 When the single parallel change over switch is parallel side device acts...
Page 93: ...89 12 2 Outline drawing...
Page 94: ...90 12 3 Generator connection diagram...
Page 95: ...91 12 4 Engine wiring diagram...
Page 96: ...92 12 5 Controller wiring diagram...
Page 101: ...97...