![Denyo DCA-150LSKE Instruction Manual Download Page 64](http://html1.mh-extra.com/html/denyo/dca-150lske/dca-150lske_instruction-manual_2485063064.webp)
- 60 -
8-1
Caution
on
battery
charge
Charging
of
loaded
battery
*
Disconnect
the
wiring
cable
from
the
battery
terminals
before
charging.
(Otherwise,
the
alternator
may
be
damaged
due
to
unusual
voltage
applied
to
the
alternator)
*
When
disconnecting
the
wiring
cables
from
the
battery
terminals,
remove
the
ground
cable
first.
(If
a
tool
touches
the
space
between
the
"+"
terminal
and
the
machine,
electric
spark
will
occur
which
is
very
dangerous)
When
connecting
the
wiring
cables
to
the
battery
terminals,
connect
the
ground
cable
last.
*
While
the
battery
is
being
charged,
open
all
the
liquid
plugs
to
discharge
the
gas.
Keep
the
battery
away
from
fire
to
prevent
unexpected
explosion.
Handle
the
battery
carefully
to
prevent
electric
sparks.
*
If
the
battery
is
overheated
(liquid
temperature
above
45
℃
),
stop
charging
for
a
while.
*
At
the
completion
of
charging,
stop
charging
immediately.
(The
relation
between
battery
charge
condition
and
specific
gravity
See
p.67)
If
the
battery
is
still
charged,
the
following
trouble
will
occur.
1)
Battery
overheat
2)
Decrease
in
battery
acid
3)
Deterioration
of
battery
performance
*
Do
not
connect
the
battery
polarity
in
reverse
(connection
of
"+"
and
"-"
or
"-"
and
"+")
to
prevent
damage
to
the
alternator
or
the
like.
Summary of Contents for DCA-150LSKE
Page 2: ...Japan...
Page 18: ...14 16 environmental base fluid level warning lamp...
Page 55: ...51 When the single parallel change over switch is parallel side device acts...
Page 93: ...89 12 2 Outline drawing...
Page 94: ...90 12 3 Generator connection diagram...
Page 95: ...91 12 4 Engine wiring diagram...
Page 96: ...92 12 5 Controller wiring diagram...
Page 101: ...97...