![Denyo DCA-150LSKE Instruction Manual Download Page 47](http://html1.mh-extra.com/html/denyo/dca-150lske/dca-150lske_instruction-manual_2485063047.webp)
- 43 -
(5)
Check
on
battery
acid
CAUTION
BATTERY
■
The battery acid is dilute sulfuric acid. Improper handling will cause unexpected
burns.
* When the battery acid gets on your clothes or skin, wash it out with a large
volume of water immediately. If it gets in your eyes, wash with a large volume
of water immediately and consult your doctor.
- In the worst case, it will put out your eyes.
Remove the battery acid plug (cap) and check the liquid level (10-12mm above the
electrodes). Supply distilled water if necessary.
(6) Checking on environmental base drain
Loosen the drain cock and drain the water
or contents collected in environmental base.
[Note]
Remove the drain to a container and dispose
the drain appropriately as industrial waste.