78
9.2 Firing table for Finesse metal ceramic (Dentsply De Trey-Mode)
(Use honeycomb firing material carrier.)
Prog.
Program
Preheat/
Drying
Preheat
Vacuum
Rate of
Firing/
Vacuum-
Firing
#
Description
Low Temp.
Time
Level
Temp. Rise High Temp. Time
Time
°C min min hPa °C/min
°C min min
311
D-FIN-Pulver- 450 03:00 03:00 50
90
800 00:30 01:00
Opaker
312 D-FIN-Pasten-
450
05:00
03:00
50
90
790
00:06
00:30
Opaker
313
D-FIN-Joint
Opaque/
675 03:00 07:00 50
35
770 00:06 00:30
Margin/margin
mod.
314 D-FIN-Korrektur- 450
05:00
03:00
50
90
760
00:06
00:30
Opaker
315 D-FIN-1
st
Main Firing 450
05:00
05:00
50
35
760
00:06
00:30
Opaque
dentine,
Dentin,
Dentine
effect
enamel,
gums
316 D-FIN-2
nd
Main Firing 450
05:00
05:00 50
35
750 00:06 00:30
Opaque
dentine,
Dentin,
Dentine
effect
enamel,
gums
317
D-FIN-Correction-
450 05:00 05:00 50
55
730 00:06 00:30
Firing
318
D-FIN-Glaze
firing/
450 03:00 03:00 –
70
750 –
00:06
Stains
*
319 D-FAC-repair
450
05:00
05:00
50
35
810
00:06
00:30
porcelain
320
D-FAC-Shade 450 03:00 01:00 –
100 730 –
01:00
stain
porcelain
D
= Dentsply-Modus
FIN =
Finesse Metal ceramic
FAC = Finesse All Ceramic
*
depending on desired degree of glaze
1
Caution!
Firing parameters not listed in the firing table must be set to “0” when entering values.
Caution! Do not use pressing socket for firing.
Notes:
Make a test firing if required, and adjust firing temperatures or times. For a large number of objects, temperatures or times must
be increased appropriately.