77
9 Preset
programs
9.1 Firing table for Ceramco 3 metal ceramics (Dentsply Mode)
(Use honeycomb firing material carrier.)
Prog.
Firing
Preheat Drying Preheat Vacuum-
Heating Firing
Vacuum Firing
Cool
No.
program temp. (min) (min) level rate temp. time time stage
(°C)
(hPa)
(°C/min)
(°C)
(min)
(min)
302
D-C3- 500 05:00
03:00
50 100 975 00:01
00:01
0
Paste
opaque
303
D-C3- 650 05:00 05:00 50
70
965 00:01 00:01 0
Powder opaque
304
D-C3- 650 05:00 05:00 50
70
965 00:01 00:01 0
Margin
305
D-C3-Opaque
650 05:00 05:00 50
45
930 00:01 01:00 0
dentine/
Dentine
effect/
Dentine
enamel
306
D-C3-Glaze
650 03:00 03:00 0
45
920 00:00 03:00 0
without
Glaze
liquid
307
D-C3- 650 03:00 03:00 0
55
925 00:00 00:30 0
Glaze
with
mit
Glaze
liquid
308
D-C3- 650 05:00 05:00 50
55
920 00:01 00:01 0
Correction
(Add-On)
D =
Dentsply
Modus
C3 =
Dentsply Ceramco 3-metal ceramic
Firing temperatures are recommendations.
Make a test firing and adjust firing temperatures and times, if required.
For a large number of objects, temperatures or times must be increased appropriately.