BHT-805B
5.2.2 Communications Parameters
In System Mode and user programs written in BHT-BASIC, you can set the communications parameters
listed below.
Port IrDA
Interface
Transmission speed
9600, 19200, 38400, 57600, 115200,
460800
(Note1)
or 4M
(Note2)
bps
Character length
8 bits
Vertical parity
None
Stop bit length
1 bit
Note1:
460800 bps is only possible when communicating from one BHT-805B unit to another, or
with the CU-821.
Note2:
4 Mbps is only possible for communication with the dedicated CU-811 unit.
System Mode
Refer to “Chapter 4 System Operation” – “4.5.6 Set System Menu.”
BHT-BASIC
To set the transmission speed, character length, vertical parity, and stop bit length (For the IrDA interface,
set the transmission speed only), use the OPEN “COM:” statement in BHT-BASIC.
OPEN “COM: ... “
OPEN “COM1: ... “
Through the interface port opened by the OPEN “COM:” statement, the
XFILE
statement transmits a
designated file.