![Denso BHT-805B User Manual Download Page 115](http://html1.mh-extra.com/html/denso/bht-805b/bht-805b_user-manual_2483226115.webp)
BHT-805B
[7]
Communication test
Use the following procedure to perform a communication test.
1.
Select “7: COMMUNICATION” at the TEST menu and then press the
ENT
key.
The TEST COMMUNICATION screen shown on the right displays.
“1: OPTICAL”:
Performs an IrDA communication test.
Refer to the following section for details of the above items.
Press the
BS/C
key to return to the TEST menu.
IrDA Communication Test
1.
Arrange two BHTs, one as a master station and the other as a slave station (to be tested) with
their IrDA interface ports facing each other as illustrated below.
This test involves transmitting data from the test BHT and the master BHT returning the data to the test
BHT.
Data
Max. 15 cm
Slave BHT
(to be tested)
Master BHT
2.
Select “1: OPTICAL” at the TEST COMMUNICATION menu and
then press the
ENT
key.
The TEST COMMUNICATION screen displays as shown on the right.
102
Summary of Contents for BHT-805B
Page 1: ...Barcode Handy Terminal BHT 805B User s Manual...
Page 23: ...BHT 805B 10...