Denkovi SmartDEN IP-32IN User Manual Download Page 1

 

 

SmartDEN

 

IP-32IN

 User Manual 

17 Jan 2018

 

 

-1- 

 

 

 
 
 
 
 
 
 
 
 
 

SmartDEN IP-32IN

 

Web enabled 32 Input Module

 

 

User Manual 

Date: 17 Jan 2018 

 

For firmware version: v1.26 / Jan 2018 

 

Summary of Contents for SmartDEN IP-32IN

Page 1: ...SmartDEN IP 32IN User Manual 17 Jan 2018 1 SmartDEN IP 32IN Web enabled 32 Input Module User Manual Date 17 Jan 2018 For firmware version v1 26 Jan 2018...

Page 2: ...d trademarks or trademarks of Microsoft Corporation in the United States and or other countries Apple Mac Mac OS Mac OS logo are either trademarks or registered trademarks of Apple Computer Inc in the...

Page 3: ...res 4 2 Application examples 5 3 Technical parameters 7 4 Connectors ports and led indicators 9 5 Installation 9 6 Default settings 23 7 Web access 27 8 HTTP server 50 9 HTTP client 55 10 SNMP access...

Page 4: ...alog inputs Communication Fully Compatible with 10 100 1000 Base T networks Auto MDIX Protocols TCP IP HTTP DHCP DNS ICMP ping SNMPv2c Web Interface Configuration of system parameters Access current m...

Page 5: ...so on can be connected to the device In this mode SmartDEN IP 32IN acts as a server A custom client application can retrieve the current measurements using SNMPv2c or HTTP GET requests Examples of cli...

Page 6: ...ovides 16 x 16 bit counters from 0 up to 65535 attached to the digital inputs that can be used to count various not fast events for example detect when a person enters in a shop through the door Fig 3...

Page 7: ...bits 10 Value of LSB mV 10 Input impedance K 1330 Sample period ms Min 25 Max 300 Protection against reverse polarity Yes No communication HTTP SNMP is taking place with the module Intensive communica...

Page 8: ...Accuracy 0 5 C Sample period ms Min 25 Max 300 No communication HTTP SNMP is taking place with the module Intensive communication HTTP SNMP with the module Table 7 Network Parameter Value Network para...

Page 9: ...connectors ports and led indicators Figure 4 Device overview 5 Installation This device must be installed by qualified personnel This device must not be installed directly outdoors Installation consis...

Page 10: ...ting Figure 5 Mounting the device to DIN rail SmartDEN IP 32IN can be mounted to a standard 35mm by 7 55mm DIN rail Attach the module to the DIN rail by hooking the hook on the back of the enclosure t...

Page 11: ...Figure 6 SmartDEN IP 32IN power supply SmartDEN IP 32IN must be with voltage either 12VDC or 24VDC stabilized and filtered After power on the power led must be on and STATUS indicator must start blin...

Page 12: ...2IN does not accept AC supply voltage It is highly recommended to check the power supply source parameters before supply the module The power supply equipment shall be resistant to short circuit and o...

Page 13: ...SmartDEN IP 32IN User Manual 17 Jan 2018 13 5 3 Connecting inputs Figure 8 Connecting SPST NO output dry contact sensors switches buttons door sensors and so on to the digital inputs...

Page 14: ...SmartDEN IP 32IN User Manual 17 Jan 2018 14 Figure 9 Connecting PNP output digital sensors requiring supply voltage 12 24V DC to the digital inputs...

Page 15: ...SmartDEN IP 32IN User Manual 17 Jan 2018 15 Figure 10 Connecting 0 20mA output analog sensors to the analog inputs...

Page 16: ...SmartDEN IP 32IN User Manual 17 Jan 2018 16 Figure 11 Connecting analog sensors with output from 0 up to 10V DC to the analog inputs requiring power supply voltage 5V DC...

Page 17: ...SmartDEN IP 32IN User Manual 17 Jan 2018 17 Figure 12 Connecting analog sensors with output from 0 up to 10V DC to the analog inputs requiring power supply voltage 12 24V DC...

Page 18: ...SmartDEN IP 32IN User Manual 17 Jan 2018 18 Figure 13 Connecting thermoresitor NTC sensors type B57500M to the analog inputs...

Page 19: ...n SmartDEN IP 32IN supports AUTO MDIX so either crossover or straight through network cable can be used Figure 14 Connecting SmartDEN IP 32IN to a computer directly This is the recommend initial conne...

Page 20: ...rectly to the computer Next you have to change your PC s IP address You can google how to change you computer IP settings or just visit this web page http www howtochangeipaddress com changeip php For...

Page 21: ...IP 32IN User Manual 17 Jan 2018 21 The next step is to enter into IPv4 properties Figure 17 Enter in IPv4 properties section Set the IP address of your PC to be in the same network Figure 18 Set the I...

Page 22: ...e in your browser 192 168 1 100 Figure 19 Open the device via browser If the network settings are O K the log in page should appear Figure 20 Login page SmartDEN IP 32IN modules connected locally can...

Page 23: ...Filter sec 0 Monitoring Timeout sec 3 Max Monitoring Errors 5 Network Settings DHCP Disabled IP Address 192 168 1 100 Gateway 192 168 1 1 Subnet Mask 255 255 255 0 Primary DNS 192 168 1 1 Secondary D...

Page 24: ...ess 0 0 0 0 Trap Receiver Port 162 Trap Community Trap Sending Level Triggered Digital Inputs Description DI n where n 1 16 Counter 0 Filter ms 0 SNMP Trap Disabled SNMP Trap Value 0 Off Remote Relay...

Page 25: ...SmartDEN IP 32IN User Manual 17 Jan 2018 25 Remote Relay Mode Normal...

Page 26: ...returned back as those in point 6 1 from the current document Figure 22 Loading the default settings 1 Turn off the power supply of the device 2 Press and hold the default button 3 Turn on the power...

Page 27: ...23 Web access To access the setup pages run a web browser Internet Explorer Mozilla Firefox or similar and enter the SmartDEN IP 32IN IP address for example http 192 168 1 100 Figure 24 Open via brows...

Page 28: ...ails Note The default password is admin passwords are case sensitive Note When the password is entered it is transmitted across the network in encrypted form so eavesdropping on the data transmission...

Page 29: ...SmartDEN IP 32IN User Manual 17 Jan 2018 29 7 2 Menu The main menu consists of the following items located in the left window frame Figure 26 Navigation menu...

Page 30: ...herefore set passwords in a secure environment where you can make sure that no one is eavesdropping Subsequent transmissions of the password to login onto the device are encrypted and safe Temperature...

Page 31: ...SmartDEN IP 32IN It needs to be manually assigned only if DHCP is disabled With DHCP enabled this field displays the currently assigned address Gateway this specifies the IP address of the gateway ro...

Page 32: ...address and subnet mask of the HTTP client Access MAC Address this field can be used to restrict the HTTP XML JSON access by specifying the MAC address of the HTTP client Session Timeout min Specifies...

Page 33: ...ettings to apply It is highly recommended to log out from the web server after finishing the parameters setup If you don t want to restrict the HTTP XML JSON access by IP address set the Access Mask t...

Page 34: ...e the HTTP server is located on some remote machine and it must process the XML file containing the input values sent via POST request by the SmartDEN IP 32IN module Parameters are o Enable activate t...

Page 35: ...is IP controller Wi Fi Relays and smartDEN relay modules o Remote Board Address the IP address or domain name of the remote board o Remote Board Port the remote board HTTP listening port o Remote Boar...

Page 36: ...can be set from this web page Enable Trap global parameter that enables or disables sending traps to the server Trap Receiver IP Address the IP address of the trap server Trap Receiver Port determines...

Page 37: ...is parameter The values which can be for this parameters are from 0 up to 65535 The counters are software and not hardware Due to this there are some considerations which must be taken in mind when wo...

Page 38: ...be from 0 up to 200 ms SNMP Trap determines if the Digital Input will send traps or not SNMP Trap Value this parameter determines how the traps will be sent and how counter will work o 0 Off If the p...

Page 39: ...its from 0 to 1 Figure 35 Traps and counter when SNMP Trap Value is 1 on o 2 Both If the parameter Trap Sending is set with value Level Triggered then the trap message is sent constantly every 5 secon...

Page 40: ...he list from page Remote Services Commands for Remote Relay Control are sent o When the digital input state is changed o After reset of SmartDEN IP 32IN o When new relay is selected from the field Rem...

Page 41: ...elay Mode parameter is Normal o Inversed when the digital input is ON the relay will be OFF Then the input is OFF the relay will be ON Figure 38 Controlling remote relay when Remote Relay Mode paramet...

Page 42: ...lue for example m A KG V max 4 chars Low Threshold the low threshold for the measured value range from 9999 to High Threshold High Threshold the high threshold for the measured value range from Low Th...

Page 43: ...is changed and the Analog Input measured value is less or equal than the new value of Low Threshold o When the parameter High Threshold is changed and the Analog Input measured value is greater or equ...

Page 44: ...control command for the remote relay o Normal when the rising analog input value crosses the High Threshold the remote relay digital output will be OFF 0 When the falling value crosses the Low Thresho...

Page 45: ...he sensor value otherwise must be left with value of 0 Low Threshold C F the low threshold limit for this input range from 55 C 67 F up to High Threshold High Threshold C F the high threshold limit fo...

Page 46: ...mperature Input value is less or equal than the new value of Low Threshold o When the parameter High Threshold is changed and the Temperature Input value is greater or equal than the new value of High...

Page 47: ...sing Temperature Input value crosses the High Threshold the remote relay digital output will be OFF 0 When the falling value crosses the Low Threshold the remote relay digital output will be ON 1 Fig...

Page 48: ...SmartDEN IP 32IN User Manual 17 Jan 2018 48 Save button once you have changed the settings as required click this button 7 12 Monitoring Figure 49 Monitoring page 7 13 Logout Figure 50 Log off...

Page 49: ...SmartDEN IP 32IN User Manual 17 Jan 2018 49 7 14 Reboot Figure 51 Reboot...

Page 50: ...use this mode XML JSON access should be enabled The login process differs depending on the selected Encrypt Password option 8 1 XML access 8 1 1 XML login encrypted password In this mode a two step l...

Page 51: ...ncrypted parameter with the request http 192 168 1 100 current_state xml pw admin Getting the LoginKey in the answer in this mode means that the provided password is wrong or the login session has bee...

Page 52: ...SmartDEN IP 32IN User Manual 17 Jan 2018 52 Figure 53 XML file with current measurements...

Page 53: ...n custom application is available upon request 8 2 2 JSON login non encrypted password The password should be passed as non encrypted parameter with the request http 192 168 1 100 current_state json p...

Page 54: ...SmartDEN IP 32IN User Manual 17 Jan 2018 54 Figure 54 JSON file with current measurements...

Page 55: ...push notifications mode is designed in order to help solving cases like remote monitoring and Internet Ethernet logging The SmartDEN IP 32IN acts like a client and it sends pushes HTTP POST messages...

Page 56: ...the posted XML file content Example body content is shown below xml version 1 0 encoding UTF 8 CurrentState DigitalInput1 Name DI1 Name Value 0 Value Count 0 Count DigitalInput1 DigitalInput2 Name DI2...

Page 57: ...0 Name DI10 Name Value 0 Value Count 0 Count DigitalInput10 DigitalInput11 Name DI11 Name Value 0 Value Count 0 Count DigitalInput11 DigitalInput12 Name DI12 Name Value 0 Value Count 0 Count DigitalIn...

Page 58: ...Value Measure 0 0 DegF Measure AnalogInput3 AnalogInput4 Name AI4 Name Value 0 Value Measure 20 1 M Measure AnalogInput4 AnalogInput5 Name AI5 Name Value 0 Value Measure 1 2 RH Measure AnalogInput5 An...

Page 59: ...e Value Value TemperatureInput7 TemperatureInput8 Name TI8 Name Value Value TemperatureInput8 Device Name SMARTDEN IP32IN Name MAC E8 EA DA 00 18 B7 MAC Device CurrentState 9 2 Remote Relay Control mo...

Page 60: ...le must see the IP of the Remote Relay Board in order to work in this mode In case of LAN both modules must be in same local network segment In case of WAN the Remote Relay Board address must be stati...

Page 61: ...SPLAYSTR ING x 7 1 2 0 Version read only Current firmware version DISPLAYSTR ING x 7 1 3 0 Date read only Current firmware version build date DISPLAYSTR ING 10 2 Setup Table 10 Digital Inputs OID s St...

Page 62: ...put Min read write Analog Input Min Value maxlen 7 DISPLAYST RING SIZE 0 7 x 7 2 2 1 8 0 x 7 2 2 1 8 7 AnalogInput Max read write Analog Input Max Value maxlen 7 DISPLAYST RING SIZE 0 7 x 7 2 2 1 9 0...

Page 63: ...l Table 13 Control OID s OID Name Access Description Syntax x 7 3 1 0 DigitalInputs State read write Digital Inputs State 0 65535 INTEGER32 0 65535 x 7 3 2 0 Reboot read write Reboot smartDEN IP 32IN...

Page 64: ...32IN User Manual 17 Jan 2018 64 x 7 4 4 0 TrapCommunity read write Community in Sending Trap DISPLAYSTRIN G SIZE 0 7 x 7 4 5 0 TrapSending read write Trap Sending Level Triggered 0 Edge Triggered 1 I...

Page 65: ...ions of the password to login onto the device are encrypted and safe The only case when the password is transmitted across the network in the open is when it is being changed and submitted in General...

Page 66: ...SmartDEN IP 32IN User Manual 17 Jan 2018 66 12 Mechanical drawing Figure 59 Device size...