X25: Digital Inputs / Outputs (Additional)
X25 (J12 internally) is used to wire further additional general purpose digital I/Os (16 inputs, and 8 outputs).
X25: D-sub DC-37F
Mating: D-sub DC-37M
19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
Pin #
Symbol
Function
Description
1
GPIN33
Input
Input 33
2
GPIN35
Input
Input 35
3
GPIN37
Input
Input 37
4
GPIN39
Input
Input 39
5
GPIN41
Input
Input 41
6
GPIN43
Input
Input 43
7
GPIN45
Input
Input 45
8
GPIN47
Input
Input 47
9
IN_COM_33-40
Common 33-40
Input 33 to 40 Common
10
OUT_RET
Return
Output Return
11
COM_EMT
Input
Common Emitter
12
GPO17-
Output
Sourcing Output 17
13
GPO18-
Output
Sourcing Output 18
14
GPO19-
Output
Sourcing Output 19
15
GPO20-
Output
Sourcing Output 20
16
GPO21-
Output
Sourcing Output 21
17
GPO22-
Output
Sourcing Output 22
18
GPO23-
Output
Sourcing Output 23
19
GPO24-
Output
Sourcing Output 24
20
GPIN34
Input
Input 34
21
GPIN36
Input
Input 36
22
GPIN38
Input
Input 38
23
GPIN40
Input
Input 40
24
GPIN42
Input
Input 42
25
GPIN44
Input
Input 44
26
GPIN46
Input
Input 46
27
GPIN48
Input
Input 48
28
IN_COM_41-48
Common 41-48
Input 41 to 48 Common
29
COM_COL
Input
Common Collector
30
GPO17+
Output
Sinking Output 17
31
GPO18+
Output
Sinking Output 18
32
GPO19+
Output
Sinking Output 19
33
GPO20+
Output
Sinking Output 20
34
GPO21+
Output
Sinking Output 21
35
GPO22+
Output
Sinking Output 22
36
GPO23+
Output
Sinking Output 23
37
GPO24+
Output
Sinking Output 24