Delta Elektronika SM120-25D Product Manual Download Page 19

OPERATING - TROUBLE SHOOTING - CALIBRATING

SM3000

Page 4 - 8

DELTA ELEKTRONIKA B.V.

rev. February 2018

CALIBRATION

1)

GEN ERAL

The power sup plies are fac tory cal i brated
and nor mally need no fur ther cal i bra tion.

2)

METER  CAL I BRA TION

DIG I TAL  ME TERS
The zero in di ca tion can be cal i brated with
R712 and R716, the full scale in di ca tion can
be cal i brated with R706 and R708 on P388
(see fig. 4 - 19).

3)

SPE CIAL  CAL I BRA TIONS

The fol low ing cal i bra tions must be done by
qual i fied  per son nel  only.  Wrong  cal i bra tion
causes  mal func tion.  These  cal i bra tions  are
only needed af ter spe cial re pairs. 

Warn ing  !

Dam age caused by wrong cal i bra tion is not
war ranted.

CAL I BRATING  MAX.  CUR RENT  RANGE
or  CAL I BRATING  CC  MON I TOR  FULL

SCALE.
The max. out put cur rent can be cal i brated
with R686. R686 is lo cated on P432 (see
fig. 4 - 20).
Pro gram CC in put with ex actly 5.00 V. Set
out put volt age to a low value, en sur ing the
power sup ply is in CC mode. Mea sure the
out put cur rent with an ac cu rate shunt. Cal i -
brate the cur rent with R686 ex actly on the
rated max. cur rent.

Warn ing!

 Wrong cal 

bra 

tion can dam 

age

the unit.

CAL I BRATING  THE  CC  MON I TOR  OFF -
SET.
With R652 on P384 the off set of the CC mon -
i tor volt age can be cal i brated (see fig. 4 - 21). 
The unit has to be un loaded, the out put volt -
age set on a low value. Mea sure the off set
volt age of the CC mon i tor on the prog. con -
nec tor. Cal i brate the off set on a neg a tive
value be tween –10 mV and zero mV.

Warn ing!

 wrong cal i bra tion can dam age the 

unit.

4)

SPARE PARTS

When or 

der 

ing spare parts please state:

Model,  Se rial  num ber,  Com po nent  num ber
and  Com po nent  de scrip tion.

Ex am ple:

-

Model .............SM

 

30-100

 

D

-

Se rial  no. ........Sn821701900017

-

BSU no...........Bs816802900036

-

Com po nent.....D300

-

Description. ....BYV52-PI-200

fig.  4 - 19  Me ter cal i bra tion with 25-turn potmeters on P388

fig. 4 - 20 Cal i brating max. cur rent on P432                           

fig. 4 - 21  On P384, CC mon i tor can be cal i brated

Summary of Contents for SM120-25D

Page 1: ...rlands www DeltaPowerSupplies com Tel 31 111 413656 SM3000 series PRODUCT MANUAL Contents 1 Datasheet 2 Safety Instructions 3 Descriptions 4 Operating Trouble Shooting Calibration 5 EC Declaration of...

Page 2: ...ution 3 When programming a high voltage unit directly via a PC or via a network connection either ground the negative power output or use a safety isolated interface For more information and schematic...

Page 3: ...d separately to recycle it responsibly to promote the sustainable reuse of material resources 11 Removal of safety covers Safety cover s are used to cover potentially hazardous voltages Observe the fo...

Page 4: ...2 INPUT VOLTAGE The power supplies have a wide input volt age range The units need a 3 phase input voltage but no neutral connection is required The units can also operate on one phase but at 90 of t...

Page 5: ...programming The inputs have a protection circuit formed by a series resistor and a parallel zener see fig 3 7 The capacitor limits the speed to a safe value Note that the analog inputs and outputs ar...

Page 6: ...gh 13 PROGRAMMING SPEED The response time is measured with a step waveform at the CV prog input Programming from a low to a high output voltage is nearly load independent but programming down to a low...

Page 7: ...gh energy pulse of about 300 V If there is an electrical connection between the output and the input through the oscilloscope you will get a false reading The suppression for the SM120 25D is lower bu...

Page 8: ...tch shuts down the output in case of insufficient cooling After cooling down the unit will start working again The thermal protection circuit protects 2 parts separately in the unit the switching tran...

Page 9: ...recommended for more than 3 units or in combination with Fast Programming option Consult factory for a solution 29 REMOTE SENSING The voltage at the load can be kept constant by remote sensing This fe...

Page 10: ...ure and full load the fan will run at a very low speed The fan does not operate on no load Normally at 50 C ambient and full load the fan will not work at full speed Since the fan is over rated it wil...

Page 11: ...ITER circuit so no large inrush cur rent will flow As soon as the voltage is sufficiently high the power supply starts working and the series resistor is bypassed by a relay contact The operating swit...

Page 12: ...mended to set the OVP on 24 3 27 V Check that the cooling of the unit is not obstructed 2 ANALOG PROGRAMMING Put the appropriate switch es in the position PROGRAM Connect the programming voltage sour...

Page 13: ...erminals so the OVP setting should be increased by the total voltage drop in the load leads 7 BATTERY CHARGER The CV CC regulated power supplies are ideal battery charg ers Once the output is set at t...

Page 14: ...ended for more than 4 units consult factory for using more than 4 power supplies in parallel First connect output terminals and test system in normal paral lel operation Ensure that all power connecti...

Page 15: ...ON For complex combinations as mixed series parallel always use the MASTER SLAVE SERIES ADAPTER product See fig 4 14 for an example of how to connect 2 units in se ries in parallel with 2 units in ser...

Page 16: ...ly to dry before switching it on again 3 GALVANIC INDUSTRY For using the power supplies in the galvanic industry it is strongly recommended to take precautions against an aggressive environ ment An ag...

Page 17: ...nt is flowing through pin 1 of the prog connector Please check why current is flowing through pin 1 see also next paragraph 4 and fig 4 17 4 PROGRAMMING OFFSETS Unwanted offsets in the programming can...

Page 18: ...ry to re pair P430 except for D400 D401 F400 and F401 but send P430 for repair or ask for replacement 10 CHECK POINTS IN CASE OF A SERIOUS FAILURE Check output diodes Defective diodes give a short SM...

Page 19: ...h exactly 5 00 V Set output voltage to a low value ensuring the power supply is in CC mode Measure the output current with an accurate shunt Cali brate the current with R686 exactly on the rated max c...

Page 20: ...al EN 55022 Radiated and conducted Class B EN 61000 3 3 Voltage fluctuation and flicker EN 61000 6 1 Generic Immunity residential light industrial EN 61000 6 2 Generic Immunity industrial environment...

Reviews: