SM3000

OPERATING - TROUBLE SHOOTING - CALIBRATING

rev. February 2018

DELTA ELEKTRONIKA B.V.

Page 4 - 3

Note: The 

SM300-10D

 needs an ex tra par al lel di ode on the

out put, with out this di ode the in ter nal di ode will still blow. For
this di ode 2 par al leled BYT261-PIV-400 from ST can be used. 
The SM300-10D with op tion P023 has an ex tra di ode built-in. 

8)

RE MOTE SHUT DOWN / OVER CUR RENT TRIP

The  Remote ShutDown can be op er ated with +5 V or a re lay
con tact (see fig. 4 - 10).

Using the Remote ShutDown in put, an 

Over Cur rent Trip

could be made (see fig. 4 - 10).

9)

MASTER / SLAVE SERIES OP ER A TION

For se ries  op er a tion  the 

MAS TER  /  SLAVE  SE RIES  ADAP-

TER

 

(

δ

-prod uct)

 must be used (see fig. 4 - 11).

First, con nect out put ter mi nals and test sys tem in 

nor mal  se -

ries

 op er a tion.  En sure that all (out put) power con nec tions are

re li able. An in ter rup tion of one of the power leads can cause a
fuse to blow in the unit, see ''trou ble  shoot ing''.

The volt age drop in the con nect ing leads be tween the units
should be kept < 10 mV.

Sec ond, switch off all units. Con nect units as shown in fig. 4 -
12. Use stan dard 15 pole (1:1) 

shielded ca bles

.

The max. num ber of slaves is only lim ited by the max. to tal volt -
age of 600 V.

10)

MASTER  /  SLAVE  PAR AL LEL  OP ER A TION

Note: Mas ter / Slave par al lel is not rec om mended for more
than 4 units, con sult fac tory for us ing more than 4 power
sup plies  in  par al lel.

First con nect out put ter mi nals and test sys tem in 

nor mal  par al -

lel

 op er a tion. En sure that all power con nec tions are re li able. An 

in ter rup tion of one of the (out put) power leads can cause a fuse
to blow in the unit, see “trou ble shoot ing”.

Sec ond, switch off all units. Plug in prog. connectors with the
con nec tions  ac cord ing  to  fig.  4 - 13 (buss bar to pol ogy). Al ways
use a 

shielded ca ble

. The shield ing must be con nected to the

case of the supply.
Dis con nect the links be tween the S– and – 

of the

 

slaves only

.

If not re moved the cur rent shar ing will not be pro por tional.
Both prog. switches of the slaves should be in the po si tion PRO -
GRAM.

The pur pose of the link be tween pin 9 and 11 is to set the volt -
age limit of the slaves at max i mum.

Keep the load close to the mas ter. Keep wir ing be tween mas ter
and slaves short. The volt age drop be tween a unit and the buss
bar should be kept < 10 mV.

Ac ci den tal in ter rup tion of a neg a tive load lead of a unit dur ing
op er a tion will cause fuse F600 to blow, see sec tion ‘trou ble
shoot ing’.

The S

 and S+ could be con nected to the load if de sired, but this 

is not rec om mended be cause of the com plex ity.

fig. 4 - 10

Left: Remote ShutDown with switch.

Right: Over Cur rent Trip

fig 4 - 11

The Mas ter / Slave Ser ies Adapter,

sup plied by Delta Elektronika

fig. 4 - 12

Mas ter / Slave Ser ies Connection with

two 

MASTER / SLAVE SE RIES ADAPTERS

Summary of Contents for SM120-25D

Page 1: ...rlands www DeltaPowerSupplies com Tel 31 111 413656 SM3000 series PRODUCT MANUAL Contents 1 Datasheet 2 Safety Instructions 3 Descriptions 4 Operating Trouble Shooting Calibration 5 EC Declaration of...

Page 2: ...ution 3 When programming a high voltage unit directly via a PC or via a network connection either ground the negative power output or use a safety isolated interface For more information and schematic...

Page 3: ...d separately to recycle it responsibly to promote the sustainable reuse of material resources 11 Removal of safety covers Safety cover s are used to cover potentially hazardous voltages Observe the fo...

Page 4: ...2 INPUT VOLTAGE The power supplies have a wide input volt age range The units need a 3 phase input voltage but no neutral connection is required The units can also operate on one phase but at 90 of t...

Page 5: ...programming The inputs have a protection circuit formed by a series resistor and a parallel zener see fig 3 7 The capacitor limits the speed to a safe value Note that the analog inputs and outputs ar...

Page 6: ...gh 13 PROGRAMMING SPEED The response time is measured with a step waveform at the CV prog input Programming from a low to a high output voltage is nearly load independent but programming down to a low...

Page 7: ...gh energy pulse of about 300 V If there is an electrical connection between the output and the input through the oscilloscope you will get a false reading The suppression for the SM120 25D is lower bu...

Page 8: ...tch shuts down the output in case of insufficient cooling After cooling down the unit will start working again The thermal protection circuit protects 2 parts separately in the unit the switching tran...

Page 9: ...recommended for more than 3 units or in combination with Fast Programming option Consult factory for a solution 29 REMOTE SENSING The voltage at the load can be kept constant by remote sensing This fe...

Page 10: ...ure and full load the fan will run at a very low speed The fan does not operate on no load Normally at 50 C ambient and full load the fan will not work at full speed Since the fan is over rated it wil...

Page 11: ...ITER circuit so no large inrush cur rent will flow As soon as the voltage is sufficiently high the power supply starts working and the series resistor is bypassed by a relay contact The operating swit...

Page 12: ...mended to set the OVP on 24 3 27 V Check that the cooling of the unit is not obstructed 2 ANALOG PROGRAMMING Put the appropriate switch es in the position PROGRAM Connect the programming voltage sour...

Page 13: ...erminals so the OVP setting should be increased by the total voltage drop in the load leads 7 BATTERY CHARGER The CV CC regulated power supplies are ideal battery charg ers Once the output is set at t...

Page 14: ...ended for more than 4 units consult factory for using more than 4 power supplies in parallel First connect output terminals and test system in normal paral lel operation Ensure that all power connecti...

Page 15: ...ON For complex combinations as mixed series parallel always use the MASTER SLAVE SERIES ADAPTER product See fig 4 14 for an example of how to connect 2 units in se ries in parallel with 2 units in ser...

Page 16: ...ly to dry before switching it on again 3 GALVANIC INDUSTRY For using the power supplies in the galvanic industry it is strongly recommended to take precautions against an aggressive environ ment An ag...

Page 17: ...nt is flowing through pin 1 of the prog connector Please check why current is flowing through pin 1 see also next paragraph 4 and fig 4 17 4 PROGRAMMING OFFSETS Unwanted offsets in the programming can...

Page 18: ...ry to re pair P430 except for D400 D401 F400 and F401 but send P430 for repair or ask for replacement 10 CHECK POINTS IN CASE OF A SERIOUS FAILURE Check output diodes Defective diodes give a short SM...

Page 19: ...h exactly 5 00 V Set output voltage to a low value ensuring the power supply is in CC mode Measure the output current with an accurate shunt Cali brate the current with R686 exactly on the rated max c...

Page 20: ...al EN 55022 Radiated and conducted Class B EN 61000 3 3 Voltage fluctuation and flicker EN 61000 6 1 Generic Immunity residential light industrial EN 61000 6 2 Generic Immunity industrial environment...

Reviews: