OPERATING - TROUBLE SHOOTING - CALIBRATING
SM3000
Page 4 - 4
DELTA ELEKTRONIKA B.V.
rev. February 2018
11)
PAR AL LEL OP ER A TION OF FAST PRO -
GRAMMING VER SIONS:
•
Mas ter / Slave op er a tion is not rec om mended.
•
Nor mal par al lel op er a tion can give prob lems, each com bi na -
tion has to be tested first in com bi na tion with the load.
12)
MASTER / SLAVE MIXED SERIES / PAR AL LEL
OP ER A TION
•
For com plex com bi na tions as mixed se ries - par al lel al ways
use the
MASTER / SLAVE SERIES ADAPTER
(
δ
-prod uct)
.
•
See fig. 4 - 14 for an ex am ple of how to con nect 2 units in se -
ries in par al lel with 2 units in se ries, con trolled by 1 mas ter.
•
On the par al lel slave1, fully open the CV-potmeter.
•
Note: A Mas
ter / Slave com
bi
na
tion can al
ways be pro
-
grammed, also with the
IEEE488 / RS232
con trol ler
(
PSC-488 mod ule / PSC-232
(both
δ
-prod ucts)
).
fig. 4 - 13
Mas ter / Slave par al lel connections
fig. 4 - 14
Mas ter / Slave mixed se ries - par al lel con nec tions with
two
MAS TER / SLAVE SE RIES ADAPT ERS