• Include all Storage Center primary and reserve WWPNs of system A and all Storage Center primary
and reserve WWPNs of system B in a single zone.
NOTE: Some ports may not be used or dedicated for replication, however ports that are used must
be in these zones.
Cabling SAN-Attached Host Servers
An SC4020 storage system with Fibre Channel or iSCSI front-end ports connects to host servers through
Fibre Channel or Ethernet switches.
• A storage system with Fibre Channel front-end ports connects to one or more FC switches, which
connect to one or more host servers.
• A storage system with iSCSI front-end ports connects to one or more Ethernet switches, which
connect to one or more host servers.
Connecting to Fibre Channel Host Servers
Choose the Fibre Channel connectivity option that best suits the front
‐
end redundancy requirements and
network infrastructure.
Preparing Host Servers
Install the Fibre Channel host bus adapters (HBAs), install the drivers, and make sure that the latest
supported firmware is installed.
About this task
• Contact your solution provider for a list of supported Fibre Channel HBAs.
• Refer to the
Dell Storage Compatibility Matrix
for a list of supported Fibre Channel HBAs.
Steps
1.
Install Fibre Channel HBAs in the host servers.
NOTE: Do not install Fibre Channel HBAs from different vendors in the same server.
2.
Install supported drivers for the HBAs and make sure that the HBAs have the latest supported
firmware.
3.
Use the Fibre Channel cabling diagrams to cable the host servers to the switches. Connecting host
servers directly to the storage system without using Fibre Channel switches is not supported.
Virtual Port Mode — Two Fibre Channel Fabrics with Dual 16 Gb 2-Port Storage Controllers
Use two Fibre Channel (FC) fabrics with virtual port mode to prevent an unavailable port, switch, or
storage controller from causing a loss of connectivity between host servers and a storage system with
dual 16 Gb 2-port storage controllers.
About this task
This configuration includes two fault domains, two FC fabrics, and two FC switches. The storage
controllers connect to each FC switch using one FC connection.
• If a physical port or FC switch becomes unavailable, the storage system is accessed from the switch in
the other fault domain.
• If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to
the physical ports on the other storage controller.
Connect the Front-End Cabling
55