Figure 83. Storage Controller Diagnostic LEDs
Establish a Serial Connection to the Top Storage
Controller
Create a serial connection from a computer to the top storage controller.
1.
Use the supplied RS232 serial cable (DB9 female to 3.5 mm male adapter) to connect a computer to
the 3.5 mm serial port on the top storage controller.
To connect from a computer with a USB port, use a USB to DB9 male serial adapter.
2.
Open a terminal emulator program on the computer.
NOTE: Make sure to enable logging in the terminal emulator. If an issue occurs during the
storage system deployment, save a copy of the log file to allow for troubleshooting.
3.
Configure the serial connection in the terminal emulator as shown in the following table.
Table 15. Serial Connection Settings
Setting
Value
Emulation
VT220
Column Mode
132
Line Wrapping
Off
Connection
Serial Port
Connection Type
Direct
Baud Rate
115200
Parity
None
Data Bits
8
Stop Bits
1
Flow Control
XON/XOFF
Related links
Troubleshooting the Serial Connection to a Storage Controller Module
100
Set up Storage Center Software