![Dell SC4020 Deployment Manual Download Page 134](http://html.mh-extra.com/html/dell/sc4020/sc4020_deployment-manual_79827134.webp)
Figure 120. iSCSI Ports Tab in Virtual Ports Mode
2.
Create a fault domain for each pair of redundant iSCSI ports.
a. Click
Edit Fault Domains
. The wizard displays a list of the currently defined fault domains.
b. Click
Create Fault Domain
. A dialog box opens.
c. In the
Name
field, type a name for the fault domain.
d. From the
Type
drop-down menu, select
iSCSI
.
e. (Optional) In the
Notes
field, type a description of the fault domain.
f. Click
Continue
. The dialog box displays a summary.
g. Click
Create Now
.
h. Repeat the previous steps to create additional fault domains as needed.
i. When you are finished creating fault domains, click
Return
. The
iSCSI
tab opens.
3.
Configure the iSCSI front-end ports numbered Slot 1/Port 1 and Slot 2/Port 2 on each storage
controller..
a. Set the
Purpose
field to
Front End
.
b. Set the
Fault Domain
field to the appropriate fault domain.
c. (Optional) Type a descriptive name in the
User Alias
field.
134
Set up Storage Center Software