32
About Your System
E1420
CPU Bus parity
error. Power
cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E1422
CPU # machine
check error.
Power cycle
AC.
The system BIOS has
reported a machine check
error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E1610
Power Supply #
(### W)
missing. Check
power supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supplies" on
page 161.
E1614
Power Supply #
(### W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supplies" on
page 161.
E1618
Predictive
failure on
Power Supply #
(### W). Check
PSU.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See "Troubleshooting
Power Supplies" on
page 161.
E161C
Power Supply #
(### W) lost
AC power.
Check PSU
cables.
Specified power supply is
attached to the system,
but it has lost its AC
input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 161.
Table 1-2.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 32 Tuesday, June 9, 2009 4:09 PM
Summary of Contents for PowerEdge T410
Page 1: ...Dell PowerEdge T410 Systems Hardware Owner s Manual ...
Page 60: ...60 About Your System ...
Page 155: ...Installing System Components 155 ...
Page 156: ...156 Installing System Components ...
Page 186: ...184 Jumpers and Connectors ...
Page 188: ...186 Getting Help ...
Page 198: ...196 Glossary ...
Page 204: ...202 Index ...