SMART Errors
SMART monitors the internal performance of all motors, heads, and physical disk electronics and detects
predictable physical disk failures.
NOTE: For information about where to find reports of SMART errors that could indicate hardware
failure, see the Dell OpenManage storage management documentation at
dell.com/support/
manuals
.
Smart Error Detected On A Physical Disk In A Redundant Virtual Disk
Issue:
A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective
Action:
Perform the following steps:
1.
Back up your data.
2.
Force the physical disk offline.
NOTE: If a hot spare is present, the rebuild starts with the hot spare after
the disk is forced offline.
3.
Replace the disk with a new physical disk of equal or higher capacity.
4.
Perform the
Replace Member
operation.
NOTE: The
Replace Member
operation allows you to copy data from a
source physical disk of a virtual disk to a target physical disk that is not a
part of the virtual disk. For more information about the
Replace Member
feature, see the topic
Using Replace Member And Revertible Hot Spares
.
Smart Error Detected On A Physical Disk In A Non-Redundant Virtual Disk
Issue:
A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective
Action:
Perform the following steps:
1.
Back up your data.
2.
Use
Replace Member
or set up a global hot spare to replace the disk
automatically.
NOTE: For more information about the
Replace Member
feature, see the
topic
Using Replace Member And Revertible Hot Spares
.
3.
Replace the affected physical disk with a new physical disk of equal or higher
capacity.
4.
Restore from the backup.
Replace Member Errors
NOTE: For more information about the
Replace Member
features, see the topic
Using Replace
Member And Revertible Hot Spares
.
81
Summary of Contents for PowerEdge H730P
Page 9: ...Contacting Dell 101 Documentation Feedback 101 Locating Your System Service Tag 101 ...
Page 10: ...10 ...
Page 14: ...14 ...
Page 32: ...11 backplane jumper cable connector on the backplane 32 ...
Page 38: ...38 ...
Page 70: ...70 ...
Page 84: ...Figure 5 Disk Carrier LED Indicators 1 activity LED 2 status LED 84 ...
Page 100: ...100 ...