Memory Or Battery Problem Error Message
Error Message:
Memory/Battery problems were detected. The adapter has
recovered, but cached data was lost. Press any key to continue
Probable
Cause:
The message occurs under the following conditions:
• The adapter detects data in the controller cache that has not yet been written
to the disk subsystem.
• The controller detects an Error-Correcting Code (ECC) error while performing
its cache checking routine during initialization.
• The controller discards the cache rather than sending it to the disk subsystem
because the data integrity cannot be guaranteed.
• The battery may be under charged.
Corrective
Action:
Allow the battery to charge fully to resolve this problem. If the problem persists, the
battery or controller memory may be faulty. Contact Dell Technical Support.
Firmware Fault State Error Message
Error Message:
Firmware is in Fault State
.
Corrective
Action:
Contact Dell Technical Support.
Foreign Configuration Found Error Message
Error Message:
Foreign configuration(s) found on adapter. Press any key to
continue, or ’C’ to load the configuration utility or ’F’ to
import foreign configuration(s) and continue.
Probable
Cause:
When a controller firmware detects a physical disk with existing foreign metadata,
it flags the physical disk as
foreign
and generates an alert indicating that a foreign
disk was detected.
Corrective
Action:
Press <F> at this prompt to import the configuration (if all member disks of the
virtual disk are present) without loading the
BIOS Configuration Utility
(<Ctrl>
<R>). Or press <C> to enter the
BIOS Configuration Utility
(<Ctrl> <R>) and either
import or clear the foreign configuration.
Foreign Configuration Not Found In <Ctrl> <R> Error Message
Error Message:
The foreign configuration message is present during POST but no
foreign configurations are present in the foreign view page in
<Ctrl> <R>. All virtual disks are in an optimal state
.
Corrective
Action:
Ensure all your PDs are present and all VDs are in optimal state. Clear the foreign
configuration using
<Ctrl> <R>
or
Dell OpenManage Server Administrator Storage
Management
.
CAUTION: The physical disk goes to Ready state when you clear the foreign
configuration.
75
Summary of Contents for PowerEdge H730P
Page 9: ...Contacting Dell 101 Documentation Feedback 101 Locating Your System Service Tag 101 ...
Page 10: ...10 ...
Page 14: ...14 ...
Page 32: ...11 backplane jumper cable connector on the backplane 32 ...
Page 38: ...38 ...
Page 70: ...70 ...
Page 84: ...Figure 5 Disk Carrier LED Indicators 1 activity LED 2 status LED 84 ...
Page 100: ...100 ...