After working inside your system
on page 67
Installing the cooling shroud
Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
3. If applicable, route the cables inside the system along the chassis wall and secure the cables by using the cable-securing
bracket.
Steps
1. Align the tabs on the cooling shroud with the securing slots on the chassis.
2. Lower the cooling shroud into the chassis until it is firmly seated.
Figure 22. Installing the cooling shroud
a. cooling shroud
b. touch point (2)
Next steps
1. If removed, install the full-length PCIe card.
2. Follow the procedure listed in the After working inside your system section.
Related references
on page 66
Related tasks
Before working inside your system
on page 67
Cooling fans
Your system supports six hot-swappable cooling fans.
Installing and removing system components
75