Table 6. Hard drive indicator codes (continued)
Drive-status indicator pattern
Condition
NOTE:
The drive status indicator remains off until all hard
drives are initialized after the system is turned on. Drives are
not ready for insertion or removal during this time.
Flashes green, amber, and then turns off
Predicted drive failure
Flashes amber four times per second
Drive failed
Flashes green slowly
Drive rebuilding
Steady green
Drive online
Flashes green for three seconds, amber for three
seconds, and then turns off after six seconds
Rebuild stopped
uSATA SSD indicator codes
Figure 7. uSATA SSD indicators
1. uSATA SSD activity indicator
2. uSATA SSD status indicator
3. uSATA SSD
NOTE:
If the SSD is in the Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does
not function and remains off.
Table 7. Drive status indicator codes
Drive-status indicator pattern
Condition
Flashes green twice per second
Identifying drive or preparing for removal.
Off
Drive ready for insertion or removal.
NOTE:
The drive status indicator remains off until all hard
drives are initialized after the system is turned on. Drives are
not ready for insertion or removal during this time.
Flashes green, amber, and turns off
Predicted drive failure
Flashes amber four times per second
Drive failed
Steady green
Drive online
Flashes green for three seconds, amber for three
seconds, and turns off after six seconds
Rebuild aborted
Dell PowerEdge R730 system overview