22
About Your System
Diagnostics Indicator Codes
The four diagnostics indicators on the system front panel display error codes during system startup.
Table 1-5 lists the causes and possible corrective actions associated with these codes.
Write fault
Write fault on selected
drive
Faulty diskette, diskette drive, hard
drive.
Replace the diskette. Ensure that the
diskette drive and hard-drive cables are
properly connected. See
"Troubleshooting a USB Device" on
page 83, "Troubleshooting a Hard Drive"
on page 90, or "Troubleshooting a Hard
Drive" on page 90 for the appropriate
drive(s) installed in your system.
Table 1-4.
System Messages
(continued)
Message
Causes
Corrective Actions
Table 1-5.
Diagnostic Indicator Codes
Code
Causes
Corrective Action
Possible processor failure. See "Troubleshooting the Microprocessor" on
page 92.
Memory failure.
See "Troubleshooting System Memory" on
page 88.
Possible expansion card
failure.
See "Troubleshooting Expansion Cards" on
page 91.
Possible video card
failure.
See "Troubleshooting Expansion Cards" on
page 91.
A B C D
A B C D
A B C D
A B C D
= y e l l o w
= g r e e n
= o f f