Invalid ESCD Configuration, Resources
Reallocated
System configuration data has been
ignored.
Check the System Setup configuration settings (see "Using the System
Setup Program" in the
User's Guide
).
Invalid SCSI Configuration; Daughter
Card Detected, SCSI cable not present
on connector A of the primary
backplane.
SCSI cable is loose, improperly
connected, or faulty.
Check the SCSI cable connection. If the problem persists, add or
replace the SCSI cable (see "
Getting Help
").
Invalid SCSI Configuration; Daughter
Card Detected, SCSI cable not present
on connector B of the primary
backplane.
Invalid SCSI Configuration; Daughter
Card Not Detected, SCSI cable present
on connector B of the primary
backplane.
SCSI channel B cable present;
backplane daughter card is not
installed.
Install the SCSI backplane daughter card (see "
Getting Help
").
Invalid SCSI Configuration; SCSI cable
not present on connector A of the
primary backplane
SCSI cable is loose, improperly
connected, or faulty.
Check the SCSI cable connection. If the problem persists, add or
replace the SCSI cable (see "
Getting Help
").
Keyboard controller failure
Faulty keyboard controller; faulty I/O
riser card.
See "
Troubleshooting the I/O Riser Card
" in "Troubleshooting Your
System."
Keyboard data line failure
Loose or improperly connected
keyboard cable; dirty or faulty
keyboard; faulty keyboard controller;
faulty I/O riser card.
See "
Troubleshooting the Keyboard
" and "
Troubleshooting the I/O
Riser Card
" in "Troubleshooting Your System."
Keyboard failure
Keyboard stuck key failure
Memory address line failure at
address
,
read
value
expecting
value
Faulty or improperly installed memory
modules; faulty microprocessor board.
See "
Troubleshooting System Memory
" in "Troubleshooting Your
System."
Memory double word logic failure at
address
, read
value
expecting
value
Memory high address line failure at
start address
to
end address
Memory high data line failure at
start
address
to
end address
Memory odd/even logic failure at
start
address
to
end address
Memory write/read failure at
address
,
read
value
expecting
value
Memory allocation error
Faulty application program.
Restart the application program.
Memory bank population error!
Memory modules installed are not the
same type and size in each bank;
faulty memory module(s); memory
modules are not installed sequentially.
Ensure that all banks contain memory modules of the same type and
size and that they are properly installed. Ensure that banks are
populated sequentially (see "
Memory Module Installation Guidelines
" in
"Installing System Options"). If the problem persists, see
"
Troubleshooting System Memory
" in "Troubleshooting Your System."
Memory parity failure at
start address
to
end address
Faulty or improperly installed memory
modules.
See "
Troubleshooting System Memory
" in "Troubleshooting Your
System."
Memory parity error at
address
Memory parity interrupt at
address
Memory tests terminated by keystroke
POST memory test terminated by
pressing the spacebar.
No action is required.
No boot device available
Faulty or missing CD/diskette drive
subsystem, hard drive, or hard-drive
subsystem.
See "
Troubleshooting the Diskette Drive
," "
Troubleshooting a CD
Drive
," and "
Troubleshooting Hard Drives
" in "Troubleshooting Your
System."
No boot sector on hard-disk
No operating system on hard drive.
Check the hard-drive configuration settings in the System Setup
program (see "Using the System Setup Program" in the
User's Guide
).
No microcode update loaded for
Processor
n
BIOS error.
Update the BIOS firmware (see "
Getting Help
").
No timer tick interrupt
Faulty I/O board.
See "
Troubleshooting the I/O Board
" in "Troubleshooting Your System."
Non-system disk or disk error
Faulty diskette, diskette/CD drive
assembly, hard drive, or hard-drive
subsystem; no operating system on
diskette or hard drive.
Use a bootable diskette. If the problem persists, see "
Troubleshooting
the Diskette Drive
," "
Troubleshooting a CD Drive
," and
"
Troubleshooting Hard Drives
" in "Troubleshooting Your System."
Not a boot diskette
No operating system on diskette.
Use a bootable diskette.
PCI BIOS failed to install
Loose cables to expansion card(s);
faulty or improperly installed
expansion card.
Ensure that all appropriate cables are securely connected to the
expansion cards. If the problem persists, see "
Troubleshooting
Expansion Cards
" in "Troubleshooting Your System."
PCI bus error
Faulty or improperly installed
expansion card; faulty I/O board.
See "
Troubleshooting Expansion Cards
" in "Troubleshooting Your
System."
Plug & Play Configuration Error
Embedded
xxx
Error encountered in initializing PCI
device; faulty I/O board.
Install the NVRAM_CLR jumper and reboot the system. If the problem
persists, see "
Troubleshooting Expansion Cards
" in "Troubleshooting
Your System."
Plug & Play Configuration Error PCI
Slot
n
Error encountered in initializing PCI
adapter.
Primary backplane is not present
SCSI cable is loose, improperly
connected, or faulty.
Check the SCSI cable connection. If the problem persists, add or
replace the SCSI cable (see "
Getting Help
").
Processor VID mismatching/VRM missing
Faulty, unsupported, or missing VRM
Ensure that supported VRMs of the same type are properly installed. If