About Your System
23
PCI BIOS failed to install
PCI device BIOS (Option ROM)
checksum failure is detected during
shadowing. Loose cables to expansion
card(s); faulty or improperly installed
expansion card.
Reseat the expansion cards. Ensure that
all appropriate cables are securely
connected to the expansion cards. If the
problem persists, see "Troubleshooting
Expansion Cards" on page 109.
Plug & Play Configuration
Error
Error encountered in initializing PCI
device; faulty system board.
Install the RTCRST jumper and reboot
the system. See Figure 6-1 for jumper
location. If the problem persists, see
"Troubleshooting Expansion Cards" on
page 109.
Read fault
Requested sector not found
The operating system cannot read
from the diskette or hard drive, the
system could not find a particular
sector on the disk, or the requested
sector is defective.
Replace the diskette. Ensure that the
diskette and hard drive cables are
properly connected. See
"Troubleshooting a USB Device" on
page 99, "Troubleshooting a Diskette
Drive" on page 105, or "Troubleshooting
a Hard Drive" on page 107 for the
appropriate drive(s) installed in your
system.
Remote configuration
update attempt failed
System unable to process Remote
Configuration request.
Retry Remote Configuration.
ROM bad checksum = address
Expansion card improperly installed or
faulty.
Reseat the expansion cards. Ensure that
all appropriate cables are securely
connected to the expansion cards. If the
problem persists, see "Troubleshooting
Expansion Cards" on page 109.
SATA port
n
hard disk drive
not found
SATA cables are not properly seated,
or drive missing.
See "Troubleshooting a Hard Drive" on
page 107.
Sector not found
Seek error
Seek operation failed
Faulty diskette or hard drive.
See "Troubleshooting a Diskette Drive"
on page 105 or "Troubleshooting a Hard
Drive" on page 107 for the appropriate
drive(s) installed in your system.
Shutdown failure
Shutdown test failure.
See "Troubleshooting System Memory"
on page 103.
Table 1-6.
System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 23 Monday, June 5, 2006 1:51 PM
Summary of Contents for POWER EDGE SC1430
Page 8: ...8 Contents book book Page 8 Monday June 5 2006 1 51 PM ...
Page 26: ...26 About Your System book book Page 26 Monday June 5 2006 1 51 PM ...
Page 40: ...40 Using the System Setup Program book book Page 40 Monday June 5 2006 1 51 PM ...
Page 112: ...112 Troubleshooting Your System book book Page 112 Monday June 5 2006 1 51 PM ...
Page 116: ...116 Running the System Diagnostics book book Page 116 Monday June 5 2006 1 51 PM ...
Page 156: ...156 Glossary book book Page 156 Monday June 5 2006 1 51 PM ...