Table 26. Gaseous contamination specifications
Gaseous contamination
Specifications
Copper Coupon Corrosion Rate
<300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver Coupon Corrosion Rate
<200 Å/month as defined by AHSRAE TC9.9.
Expanded operating temperature
NOTE:
For additional information about environmental measurements for specific system configurations, see Dell.com/
environmental_datasheets.
Table 27. Expanded Operating Temperature
Condition
Temperature
Continuous operation
5 °C to 40 °C at 5% to 85% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C to 35°C), the system
can operate continuously down to 5°C or as high as 40°C.
For temperatures between 35°C and 40°C, derate maximum allowable temperature by
1°C per 175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours
–5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10 °C to 35 °C), the system
can operate down to –5°C or up to 45°C for a maximum of 1% of its annual
operating hours.
For temperatures between 40°C and 45°C, derate maximum allowable temperature by
1°C per 125 m above 950 m (1°F per 228 ft).
Expanded Operating Temperature
Restrictions
●
For low-power CPUs (55 W/ 65 W), both the internal cooling fan and the external
cooling fan must be installed.
●
The operating temperature that is specified is for a maximum altitude of 30482000
m (10,0006560 ft).
●
GPU card is not supported.
●
LRDIMM is not supported.
●
Nonredundant power supplies are not supported.
●
Cabled power supply units are not supported.
●
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are
not supported.
NOTE:
When operating in the expanded temperature range, system performance may be impacted.
NOTE:
When operating in the expanded temperature range, ambient temperature warnings may be reported in the System
Event Log.
Technical specifications
37