A-4
Dell Dimension L Series Systems Reference and Troubleshooting Guide
Power
DC power supply:
Wattage . . . . . . . . . . . . . . . . . . . . . . . 145 W
45 W
Heat dissipation . . . . . . . . . . . . . . . . . 700 BTU (fully loaded system without
monitor)
Voltage (switch-selectable on
back panel) . . . . . . . . . . . . . . . . . . . . . 90 to 135 V at 60 Hz;
180 to 265 V at 50 Hz;
100 V at 50–60 Hz for Japanese systems
Japanese systems
Backup battery . . . . . . . . . . . . . . . . . . . . . 3-V CR2032 coin cell
Physical
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 cm (15.375 inches)
(15.375 inches)
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.8 cm (6.5 inches)
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 cm (13.375 inches)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.9 Kg (22 lb)
Environmental
Temperature:
rature:
Operating . . . . . . . . . . . . . . . . . . . . . . 10
°
to 35
°
C (50
°
to 95
°
F)
2
Storage. . . . . . . . . . . . . . . . . . . . . . . . –40
°
to 65
°
C (–40
°
to 149
°
F)
Relative humidity
y:
Operating . . . . . . . . . . . . . . . . . . . . . . 20% to 80% (noncondensing)
Storage. . . . . . . . . . . . . . . . . . . . . . . . 5% to 95% (noncondensing)
Maximum vibration:
vibration:
Operating . . . . . . . . . . . . . . . . . . . . . . 0.25 G at 3 to 200 Hz at 1/2 octave/min
Storage. . . . . . . . . . . . . . . . . . . . . . . . 0.5 G at 3 to 200 Hz at 1/2 octave/min
Maximum shock:
hock:
Operating . . . . . . . . . . . . . . . . . . . . . . bottom half-sine pulse with a change in
velocity of 50.8 cm/sec (20 inches/sec)
Storage. . . . . . . . . . . . . . . . . . . . . . . . 27-G faired-square wave with a velocity
7-G faired-square wave with a velocity
change of 508 cm/sec (200 inches/sec)
Table A-1. Technical Specifications
(continued)
NOTE: The Glossary in the
system Help
defines abbreviations and acronym
s.
Summary of Contents for Dimension L Series
Page 1: ...www dell com support dell com Dell Dimension L Series Systems ...
Page 10: ...xii ...
Page 24: ...1 8 Dell Dimension L Series Systems Reference and Troubleshooting Guide ...
Page 42: ...2 18 Dell Dimension L Series Systems Reference and Troubleshooting Guide Guide ...
Page 108: ...7 20 0 Dell Dimension L Series Systems Reference and Troubleshooting Guide ...
Page 114: ...A 6 6 Dell Dimension L Series Systems Reference and Troubleshooting Guide ...
Page 140: ...C 8 Dell Dimension L Series Systems Reference and Troubleshooting Guide ...
Page 156: ...E 8 8 Dell Dimension L Series Systems Reference and Troubleshooting Guide ...
Page 162: ...6 Dell Dimension L Series Systems Reference and Troubleshooting Guide ...