
V0913, 5.14
•
Yes = allowed
Backstop-die, intermediate bend
Set to allow if there may be a bend between the die and backstop.
Selection possibilities:
•
Permitted
•
If unavoidable permitted: if it results that no solutions are to be found, than it is
permitted
•
Prohibited: never allowed.
Edge tolerance
In case backstop is against flat sheet an angle tolerance is allowed (deviation from
horizontal). To be programmed in degrees of tolerance (0 - 90° input).
90 Degree tolerance
The maximum allowed deviation from vertical (90°), when the backgauge is against a
bent angle which is not 90°.
Summary of Contents for DA-66T
Page 1: ...8075 9000A Manual version V0913 DA 66T Reference Manual Operation of Version 2 3 English...
Page 30: ...V0913 2 6...
Page 45: ...V0913 2 21...
Page 74: ...V0913 4 12...
Page 122: ...V0913 7 16...
Page 138: ...V0913 8 16...
Page 156: ...V0913 9 18 calculated with respect to the end of the sheet...
Page 175: ...V0913 10 15...
Page 178: ...V0913 10 18 To program a new die tap Edit in the library and subsequently use New...
Page 186: ...V0913 10 26...
Page 189: ...V0913 10 29...
Page 218: ...V0913 A 4...