145
programming key functions
Programming
DISABLING THE DUAL CHUTE
Each Dual Chute may be disabled to allow
the station to function as a single bagging
station.
Choose this option when no coins are ex-
pected to be sorted at this particular station,
or to return to single bag configuration
should the Dual Spout become disabled.
The station will not count or display blocked
sensor error messages.
TO DISABLE:
1. Cycle the UPPER ICON CHOICE Key to
highlight the Dual Chute to be disabled.
2. Cycle the DOWN ARROW Icon Key (
) to
enable / disable.
3. Cycle the RIGHT ARROW Icon Key ( ) to
highlight the disable function.
4. Press the HOME Key to exit.
BEFORE DISABLING A DUAL CHUTE, CHECK
THE PHYSICAL POSITION OF THE DEFLEC-
TOR IN THE SPOUT TO BE CERTAIN IT IS
PLACING THE COINS INTO THE FIRST STA-
TION.
EXAMPLE: IF THE DUAL BAG IS SET UP ON
STATIONS #3 AND #4, BE CERTAIN THE DE-
FLECTOR IS SET TO PLACE THE COINS INTO
STATION #3.
IF THE DEFLECTOR IS NOT SET PROPERLY,
DO NOT FORCE
INTO POSITION, AS DAMAGE
TO THE MECHANISM WILL RESULT. CONTACT
YOUR AUTHORIZED SERVICE REPRESEN-
TATIVE FOR ASSISTANCE.
FIGURE #134
COIN ENABLE / DISABLE SCREEN
ENTER COIN VALUE:
.50
SELECT COIN TYPE:
COIN
TOKEN
TOK / VAL
DISABLE
SELECT DECIMAL POINT LOCATION:
0
0.
.0
.00
.000
DUAL BAG:
ENABLE
DISABLE
COIN DEBOUNCE:
1
2
3
4
STATION
INDICATOR
STATION #3