Settings to be made for this type of installation
Parameters
Access
Settings to be made
See chapter
INSTALLATION
Installer level
#SYSTEM
menu
EXTENDED
¼
CIRC.B
Installer level
#SYSTEM
menu
SWIM.P.
¼
"Setting the parameters specific to
If
I.TEL:
is used
I.TEL
Installer level
#SYSTEM
menu
0/1 B
MAX. CIRC. B
Installer level
#SECONDARY LIMITS
menu
Set the value of
MAX.CIRC.B
to
the temperature corresponding
to the needs of the exchanger
¼
"Professional settings", page 114
n
Controlling the pool circuit
The control system can be used to manage a swimming pool circuit
in both cases:
Case 1: The control system regulates the primary circuit (boiler/
exchanger) and the secondary circuit (exchanger/pool).
4
Connect the primary circuit pump (boiler/exchanger) to the
M
B
outlet on the connection terminal block. The temperature
MAX.CIRC.B
is then guaranteed during comfort periods on
programme
B
in summer and winter alike.
4
Connect the swimming pool sensor (package AD212) to the
S
DEP B
inlet on the connection terminal block.
4
Set the set point of the pool sensor using key
C
in the range 5 -
39°C.
Case 2: The pool has already a regulation system that is to be
kept. The control system only regulates the primary circuit
(boiler/exchanger).
4
Connect the primary circuit pump (boiler/exchanger) to the
M
B
outlet on the connection terminal block.
The temperature
MAX.CIRC.B
is then guaranteed during comfort
periods on programme
B
in summer and winter alike.
The swimming pool can also be connected to circuit
C
by
adding the AD249 option:
4
Make the connection to the terminal blocks marked
C
.
4
Set the parameters for circuit
C
.
n
Hourly programming of the secondary circuit pump
The secondary pump operates during programme
B
comfort periods
in summer and winter alike.
n
Stopping
To prepare your pool for winter, consult your pool specialist.