![Dedicated Micros DV-IP NV8 Installation Manual Download Page 126](http://html1.mh-extra.com/html/dedicated-micros/dv-ip-nv8/dv-ip-nv8_installation-manual_2462360126.webp)
126
DV-IP NV8
126
Alarm Protect sec.
This is the minimum time period in seconds (from the start of
the alarm) that is protected from being overwritten. This time will
include the alarm trigger, the pulse extension and any post alarm
recording. It will not include pre-alarm images.
Zone Input Rule
This determines which input(s) will trigger the zone alarm:
Input
This sets an input or system function as the primary alarm trigger.
Select from Preset 1- 4, Disk Low, Disk Full, Panic, Archiving
Slow, Archiving Fault, Virtual 1-16, and Keyword Channel 1 (which
will trigger the Alarm if any of the programmed keywords are
detected).
Zone OR Input
The Zone OR Input identifies an alternative input that can also be
used to trigger the zone alarm. This means an alarm trigger can
be received on the Zone Alarm Input or the Zone OR Input for the
zone to be activated.
Zone AND Input
The Zone AND Input identifies that an alarm trigger needs to be
received on both the Zone Alarm Input and the Zone AND Input
for the zone to be activated and the alarm action to the
automatically initiated.
Zone NOT Input
The unit will only issue the alarm actions if the trigger is received
on the zone alarm input and NOT on the Zone input.
Alarm 24hr
This option can be enabled for alarms that do not require change
at any time and are to remain as programmed i.e. Panic Alarm.
When this is selected, the Set, Unset and Override options
are disabled.
Entry Route Zone
This creates deferred alarms along a specified route while the
entry time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the
entry route during the countdown will result in the alarm being
triggered immediately. This allows staff entry without triggering an
alarm prior to switching the system to Set mode.
Exit route Zone
This creates deferred alarms along a specified route while the
exit time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the
exit route during the countdown will result in the alarm being
triggered immediately. This allows staff to exit without triggering
an alarm.
Exit Terminator
This will trigger the exit timer if the system is set. A countdown
timer will automatically start when the alarm is activated and
ensure the alarm system is not activated by other specified alarm
triggers for the Set time i.e. allowing a Guard to exit a building.
Entry Initiator
This will trigger the entry timer if the system is set. A countdown
timer will automatically start when the ‘primary’ alarm trigger
i.e. front door, is actioned. This ensures the alarm system is not
activated by other specified alarm triggers for the set time
Enable in Unset
Each alarm can be configured to be active when the unit is in
a specific operation mode. Enable this for the zone alarm to be
active in Unset operation mode.
Enable in Set
Each alarm can be configured to be active when the unit is in
a specific operation mode. Enable this for the zone alarm to be
active in Set operation mode.
Enable in Override
Each alarm can be configured to be active when the unit is in
a specific operation mode. Enable this for the zone alarm to be
active in Override operation mode.
Note:
Unset, Set and Override modes can be given more recognisable titles i.e. Day, Night,
Weekend via the Schedule menu (Record Settings->Schedule).