Dedicated Micros ©2009
D
V-IP Expr
es
s
Alarm Duration sec
This is the minimum time period in seconds (from the start of
the alarm) that is protected from being o�erwritten. This time will
include the alarm trigger, the pulse extension and any post alarm
recording. �t will not include pre-alarm images.
Zone �nput Rule
This determines which input(s) will trigger the zone alarm:
�nput
This sets an input or system function as the primary alarm trigger.
Select from �larms 1-32, �cti�ity 1-16, �reset 1-16, Disk �ow,
Disk Full, �anic, �rchi�ing Slow, �rchi�ing Fault, �irtual 1-16, and
�eyword Channel 1-32 (which will trigger the �larm if any or the
32 programmed keywords are detected on the selected channel).
Zone OR �nput
The Zone OR �nput identifies an alternati�e input that can also be
used to trigger the zone alarm. This means an alarm trigger can
be recei�ed on the Zone �larm �nput or the Zone OR �nput for the
zone to be acti�ated.
Zone �ND �nput
The Zone �ND �nput identifies that an alarm trigger needs to be
recei�ed on both the Zone �larm �nput and the Zone �ND �nput
for the zone to be acti�ated and the alarm action to the
automatically initiated.
Zone NOT �nput
The unit will only issue the alarm actions if the trigger is recei�ed
on the zone alarm input and NOT on the Zone input.
�larm 24Hr
This option can be enabled for alarms that do not require change
at any time and are to remain as programmed i.e. �anic �larm.
When this is selected, the Set, Unset and �verride options
are disabled.
�ntry Route Zone
This creates deferred alarms along a specified route while the
entry time is acti�e. This is in compliance with �S8418 (the �ritish
Standard for remote �ideo reporting centres). Di�erting from the
entry route during the countdown will result in the alarm being
triggered immediately. This allows staff entry without triggering an
alarm prior to switching the system to Set mode.
��it route Zone
This creates deferred alarms along a specified route while the
e�it time is acti�e. This is in compliance with �S8418 (the �ritish
Standard for remote �ideo reporting centres). Di�erting from the
e�it route during the countdown will result in the alarm being
triggered immediately. This allows staff to e�it without triggering
an alarm.
��it Terminator
This will trigger the e�it timer if the system is set. � countdown
timer will automatically start when the alarm is acti�ated and
ensure the alarm system is not acti�ated by other specified alarm
triggers for the Set time i.e. allowing a Guard to e�it a building.
�ntry �nitiator
This will trigger the entry timer if the system is set. � countdown
timer will automatically start when the ‘primary’ alarm trigger
i.e. front door, is actioned. This ensures the alarm system is not
acti�ated by other specified alarm triggers for the set time
�nable in Unset
�ach alarm can be configured to be acti�e when the unit is in
a specific operation mode. �nable this for the zone alarm to be
acti�e in Unset operation mode.
�nable in Set
�ach alarm can be configured to be acti�e when the unit is in
a specific operation mode. �nable this for the zone alarm to be
acti�e in Set operation mode.
�nable in O�erride
�ach alarm can be configured to be acti�e when the unit is in
a specific operation mode. �nable this for the zone alarm to be
acti�e in O�erride operation mode.