Equipment Specifications
A.2 VRC16 Monitor Equipment Specifications
Table A–5 (Cont.) VRC16 Monitor Description
– Horizontal period
17.707
s
– Sync pulse
1.920
s
Vertical rate timing
– Active video
13.599 ms
– Blanking interval
39 0.673 ms
– Frequency
70.069 Hz
– Front porch
0.053 ms
– Sync pulse
0.106 ms
– Vertical period
14.272 ms
Power
– ac input voltage
100-120 or 220-240 Vac
– Frequency
47 to 63 Hz
– Power consumption
150 watts maximum
Table A–6 VRC16 Monitor Operating Conditions
Temperature range
1
10°C to 40°C (50° to 104°F)
Relative humidity
10% or less to 95%
Maximum wet-bulb temperature
32°C ( 89°F)
Minimum dew-point temperature
2°C (36°F)
Altitude
10,000 ft maximum
1
Reduce maximum temperature by 1.8°C for each 1,000 meter (1.0°F for each 1,000 ft) increase in altitude.
Table A–7 VRC16 Monitor Nonoperating Conditions
Temperature range
40°C to 66°C ( 8°F to 98°F)
Relative humidity
90% to 95%
Maximum wet-bulb temperature
66°C (98°F) packaged
Altitude
12,780 m (50,000 ft) maximum
Equipment Specifications A–5