Equipment Specifications
A.3 VRM17 Monitor Equipment Specifications
Table A–8 (Cont.) VRM17 Monitor Description
– Blanking interval
3.1802
s (high scan) and 3.6574
s (low scan)
– Frequency
77.1273 kHz (high scan) and 57.384 kHz (low scan)
– Front porch
0.2446
s (high scan) and 0.2151
s (low scan)
– Horizontal period
12.9579
s (high scan) and 17.4265
s (low scan)
– Pixels displayed
1280 (high scan) and 1024 (low scan)
– Sync pulse
1.2232
s (high scan) and 1.7211
s (low scan)
Vertical rate timing
– Back porch
0.427864 ms (high scan) and 0.3834 ms (low scan)
– Blanking interval
0.505658 ms (high scan) and 0.5054 ms (low scan)
– Front porch
0.038897 ms (high scan) and 0.0174 ms (low scan)
– Lines displayed
1024 (high scan) and 76 (low scan)
– Vertical period
13.7842
s (high scan) and 13.8889
s (low scan)
– Vertical sync pulse
0.038897
s (high scan) and 0.1046
s (low scan)
– Vertical frequency
72.5562 Hz (high scan) and 72.033 Hz (low scan)
Power
– ac input
88 to 264 volts
– Frequency
47 to 63 Hz
– Power consumption
75 watts
Equipment Specifications A–7