System Troubleshooting and Diagnostics
5.2 Product Fault Management and Symptom-Directed Diagnosis
Note
One type of uncorrectable ECC error, that due to a ‘‘disown write’’,
will result in a CRD entry like those for correctable ECC errors.
The FOOTPRINT longword for this entry contains the message
‘‘Uncorrectable ECC errors due to disown write’’. The failing module
should be replaced for this error.
Example 5–6 Error Log Entry Indicating Correctable ECC Error
V A X / V M S
SYSTEM ERROR REPORT
COMPILED 12-JUN-1993 16:55:58
PAGE
1.
******************************* ENTRY
1. *******************************
ERROR SEQUENCE 2.
LOGGED ON:
SID 13001401
DATE/TIME 06-JUN-1993 09:51:13.98
SYS_TYPE 01390601
SYSTEM UPTIME: 0 DAYS 00:05:06
SCS NODE: OMEGA1
VAX/OpenVMS V5.5-2HW
CORRECTABLE MEMORY ERROR
KA680-A
CPU FW REV# 1.
CONSOLE FW REV# 3.9
REVISION
00000000
SYSTAT
00000040
MEMORY SOFT ERROR LOGGING DISABLED
FLAGS
00000008
memory sbe reduction subpacket
MEMORY SBE REDUCTION SUBPACKET
LOGGING REASON
00000001
NORMAL REPORT
PAGE MAPOUT CNT 00000003
MEMCON
0357E53F
MEMORY CONFIGURATION:
_sets enabled = 00111111
MS690-BA MEMORY MODULE # 1. 32MB SLOT 4
MS690-BA MEMORY MODULE # 2. 32MB SLOT 3
MS690-DA MEMORY MODULE # 3. 128MB SLOT 2
_total memory = 192MB
VALID ENTRY CNT 00000003
3.
CURRENT ENTRY
00000003
3.
MEMORY CRD ENTRY 1.
FOOTPRINT
00000373
(continued on next page)
5–26 System Troubleshooting and Diagnostics