34
24V
230V
INPUTS CONFIGURATION
PARAMETERS
Allocation of CHANNEL 1 of remo
tes
• 000: NONE (unused parame
ter)
• 00
1: S
TAR
T (star
t)
• 002: PEDES
TRIAN (pedestrian)
• 003: OPEN (separat
ed open)
• 004: CL
OSED (separat
ed close)
• 005: OPEN_PM (man present open) • 006: CL
OSED_PM (man present close)
• 00
7: EL
OCK
-IN (electric-lock activ
ation. See P062)
CH1
Allocation of CHANNEL 2 of remo
tes
CH2
Allocation of CHANNEL 3 of remo
tes
CH3
Allocation of CHANNEL 4 of remo
tes
CH4
Selection of type of remo
tes
• 000: HCS fix-code • 00
1: HCS r
olling-code
• 002: Dip-switch
OPERATORS CONFIGURATION
PARAMETERS
Selection type of operat
or
s
• 005: LIVI 5/2
4 - 6NET
• 006: LIVI 8/2
4 - 9NET
• 00
7: GULLIVER - REV
Unused parame
ter
Unused parame
ter
OPERATING PARAMETERS
Operat
or
s speed adjustment during slo
w
-do
wn while opening
W
arning
(for
230V
only):
F
or
operat
or
s
without
encoder
,
speedness
during
the
str
ok
e
while
opening/closing
(1
00%)
and
slo
w
do
wn
speedness
while
opening/
closing
(30%)
are
fix
ed
independently
from se
t v
alues.
15%t
ot........................
100%t
ot
Operat
or
s speed adjustment during the str
ok
e while opening
15%t
ot........................
100%t
ot
Operat
or
s speed adjustment during the str
ok
e while closing
15%t
ot........................
100%t
ot
Operat
or
s speed adjustment during slo
w
-do
wn while closing
15%t
ot........................
100%t
ot
Slo
w do
wn duration adjustment while opening
0%t
ot............................80%t
ot
Slo
w do
wn duration adjustment while closing
0%t
ot............................80%t
ot
Operat
or 1 f
or
ce adjustment while opening
(if = 1
00% obstacle de
tection deactiv
at
ed)
W
arning
(for
230V
only):
F
or
operat
or
s
without
enc
oder:
while
adjusting
the
for
ce,
obstacle
de
tection
during
the
slo
wdo
wn
is
ignored.
15%t
ot…...........................
100%t
ot
Operat
or n.
1 f
or
ce adjustment while closing
(if = 1
00% obstacle de
tection deactiv
at
ed)
15%t
ot…...........................
100%t
ot
Unused parame
ter
Unused parame
ter
Aut
omatic closing times adjustment
(if = 0 aut
omatic closing deactiv
at
ed)
0sec...................................255sec
Pedestrian aut
omatic closing time adjustment
(se = 0 pedestrian aut
omatic closing deactiv
at
ed)
0sec...................................255sec
Pedestrian str
ok
e duration adjustment
5%t
ot…...........................
100%t
ot