29
7 ADVANCED PROGRAMMING
Here are some added programming procedures relating to remotes memory management and advanced configuration of the control
inputs.
1 Deletion of memorized transmitters
1.1 Deletion of all transmitters
1. Scroll down the parameters until you visualize P004;
2. Confirm by pressing on the key;
3. When “
” is flashing, press the key for a few sec-
onds;
4. Release the key as soon as “
” stops flashing;
5. All memorized transmitters have been deleted (display
shows again P004).
1.2 How to search and delete a transmitter
1. Scroll down the parameters until you visualize P006;
2. Confirm by pressing on the key;
3. By pressing on and , keys, select the transmitter you
want to delete (eg.
);
4. When “
” flashes, confirm the deletion by pressing
the key for a few seconds;
5. Release the key when appears “
”;
6. The selected transmitter is deleted (display shows again
P006).
2 Resetting of default parameters
1. Scroll down the parameters until you visualize P007;
2. Confirm by pressing on the key;
3. When “
” flashes, press the key;
4. Release the key as soon as “
” stops flashing;
Default parameters for the configuration currently in
use are restored;
5. At the end of the operation display returns to P007.
Warning:
After you restore the default parameters, you
must program the control panel again and adjust all ope-
rating parameters, in particular, remember to properly set
the configuration of parameters (P028 - P029 - P030 –
operator configuration).
Warning:
For reversible motors with electro-brake, remem-
ber to set P062=3 at the end of the procedure.
3 Locking-Unlocking access to programming
By using a “dip-switch” remote (regardless of the type of remotes already memorized) it’s possible to lock-unlock access to the program-
ming of the control panel to avoid tampering. The remote setting is the locking-unlocking code verified by the control board.
3.1 Locking access to programming
1. Scroll through the parameters with the buttons
and until the display shows P008;
2. Access the parameter by pressing the button ;
3. The display shows alternately the writing
to indicate that the control board
is waiting for the transmission of the block code;
4. Within 10 seconds press CH1 on the “TX Master”,
the display shows
before returning
to the list of parameters;
5. Access to programming is locked.