The Redundancy function of the 480, 481, and 482 DriveRack™ units is the very definition of
the old saying that you can never be too safe. This unique function of the DriveRack™ units
ensure that programming information in the 480, 481 and 482 DriveRack™ units is safe guard-
ed in the event of any unfortunate malfunction. Simply put, this means that the program
information within any 480, 481 or 482 DriveRack™ is constantly being backed up and stored
not only into the memory of the selected unit, but also the master unit of the DriveRack™
network as well as the 480R (if used) and the PC GUI. Simply pull the unit out, and insert a
new unit in its place. The following information will provide you with ways to optimize this
priceless feature.
• To enable the Redundancy feature, enter the Utility menu by pressing the Utility button
and then using the
NEXTPG
and
PREVPG
buttons to move to page 11 of the utility
menu. Use the
PARAMETER 1
knob to engage the Redundancy Mode. The display will
now appear as follows:
• At this point, the master unit, 480R (if used) and the PC Interface (if used) is/are now
recording any activity that takes place within the network of units.
Replacing Units
• If a DriveRack™ unit needs to be taken out of the network backbone, the master unit
automatically stores the unit’s information until the unit is either returned or a replacement
unit is put in its place within the network.
• Once a DriveRack™ unit is inserted, the master unit will automatically download the last
information that it received from the corresponding unit, regardless of whether the editing
information had been stored.
•
NOTE:
Anytime a unit is replaced, the same identification number
must
be assigned to
the replacement unit in order for the master unit to recognize and send information.
7.4 Redundancy
Network Functions
SECTION 7
DriveRack
™
67
DriveRack™ User Manual
Summary of Contents for DriveRack 480
Page 1: ...User Manual CompleteEqualization LoudspeakerManagementSystem 480 481 482 480R...
Page 6: ...INTRO CUSTOMER SERVICE INFO Defining the DriveRack WARRANTY INFO INTRODUCTION DriveRack...
Page 11: ...Getting Started Section 1 DriveRack...
Page 19: ...EDITING FUNCTIONS Editing Functions Section 2 DriveRack...
Page 23: ...2 5 Navigating the EQ Sections Editing Functions Section 2 DriveRack 13 DriveRack User Manual...
Page 24: ...Editing Functions 14 Section 2 DriveRack 2 6 Navigating the XOVER DriveRack User Manual...
Page 25: ...2 7 Navigating the RTA Editing Functions Section 2 DriveRack 15 DriveRack User Manual...
Page 26: ...Editing Functions 16 Section 2 DriveRack 2 8 Navigating the Delay DriveRack User Manual...
Page 30: ...CONFIGURATION FUNCTIONS SOFTWARE Section 3 DriveRack...
Page 40: ...DETAILED PARAMETERS PARAMETERS Section 4 DriveRack...
Page 52: ...STORING PROGRAM CHANGES Storing Programs Section 5 DriveRack...
Page 56: ...UTILITIES SECTION Utilities Section 6 DriveRack...
Page 66: ...NETWORK FUNCTIONS Network Functions DriveRack...
Page 82: ...480R Remote Controller Section 8 DriveRack...
Page 90: ...APPLICATION GUIDE Section 9 DriveRack...
Page 97: ...Appendix DriveRack...
Page 114: ...DriveRack User Manual 106 Appendix A DriveRack A 9 Input and Output Diagrams...