32 Installation
(for qualified installers only)
© Travis Industries
4140805
100-01384
Wiring the Power Exhaust Assembly
The power exhaust assembly consists of a power vent and damper. Refer to the wiring diagram on
page 60 for wiring details.
Connect the power exhaust power line (sheathed three-wire electrical line) to the capacitor and
blower as shown below.
Remove the cover plate on the
exhaust blower housing.
Route the electrical line through
the romex clamp and attach the
120v wiring as detailed in the
wiring diagram below. After the
cover is replaced, tighten the
clamp to secure the wiring.
WARNING - BLOWER CAPACITOR WILL RETAIN A CHARGE
Once power is supplied to the blower capacitor, it will retain a charge for approximately 5 minutes, even
after power is shut off. Take care when working with this circuit, especially with the hot (black) wire and
circuit board/wiring inside the fireplace.
Romex
Clamp
Fireplace Junction Box
Molex (installed
in
fireplace)
Exhaust Blower Junction Box
Black
White
Green
White
Capacitor
Green
Black
Black
Black
Black
White
Green
Red
Blower