10
Features and Specifications
© Travis Industries
4140805
100-01384
Dimensions – Full Bay Configuration
(a)
Air Intake
- 6” Diameter, Centered on Fireplace, Left or Right Side (determined at time of order)
(b)
Exhaust
- 10” or 8” Diameter B-Vent (determined by exhaust blower type), Centered on Fireplace
(c)
Gas Inlet
– Location is determined at time of order (can be relocated)
(d)
Electrical Junction Box
– On both sides (location determined at time of order – can be relocated), includes
120v input, exhaust vent power/harness, on-off LED harness
(e)
Gas Control Valve
Horizontal Dimensions
Version
Overall Width (x)
Exhaust Location (y)
BTUs
48” Full Bay
48.125” (1223mm)
24” (610mm)
43,500
60” Full Bay
60.125” (1528mm)
30” (762mm)
58,000
72” Full Bay
72.125” (1832mm)
36” (915mm)
72,500
20"
508mm
Front
avant
Right
droit
Rear
arrie're
Left
a' gauche
b
11"
280mm
5.75"
(147mm)
16.375"
416mm
x
y
a
e
d
c
d
c
Version
Length
a
16.375"
416mm
12" Glass
41.125" (1045mm)
20" Glass
49.125" (1286mm)
30" Glass
59.125" (1502mm)
36" Glass
65.125 (1655mm)
12" (305mm)
20" (508mm)
30" (762mm)
36" (915mm)