Installation
(for qualified installers only)
43
© Travis Industries
4140805
100-01384
Rheostat Adjustment
Most vent configurations will require no adjustment to the rheostat.
If your flame is especially blue
or short after 20 minutes, you may need to adjust the rheostat. Contact Travis Industries for further
details before adjusting the rheostat.
NOTE
: The exhaust blower will run on high for approximately 30 seconds once the fireplace is turned on
(pre-purge). After 30 seconds the burner will turn on and the rheostat controls the speed of the exhaust
blower.
NOTE: Make sure to re-install the rotating plate correctly. If you put it on upside-down it will not calibrate
correctly.
Restrictor Installation
Most vent configurations will require no restrictor.
If your flame is especially blue or short after 20
minutes, you may need to install the restrictor (it is shipped loose inside the owner’s pack). Contact
Travis Industries for further details before installation.