Installation
(for qualified installers only)
35
© Travis Industries
4140805
100-01384
Installing the On-Off Switch and LED Controller
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.
The included junction box is used to mount the on-off switch and LED controller. Mount the junction
box in an accessible location to allow the user to operate the fireplace.
Route the On-Off LED harness to the junction box (harness is available in various lengths – see page
13). Route the wires through the junction box and attach the connections to the LED controller and
on-off switch. NOTE: Install 3” to 6” of slack in the harness wires to allow for switch/controller access
and removal.
Attach the on-off switch and LED controller to the junction box with the included screws.
The included cover plate should be installed after the fireplace has been tested and the installation
finalized.
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
Secure the On-Off LED harness
to the junction box with lock ties.
This prevents the wires from
slipping out of the junction box
during installation. Take care to
prevent damage to wires.
Double-Gang
Junction Box
Cover Plate, On/Off Switch,
LED Controller, and Screws.
On-Off LED Harness
(Available in Various Lengths)
Do not route the wires over the top of
the fireplace.