3.3 Pump 1 (Two speed, no 24HR circulation pump fitted)
Pump 1 is controlled by just one touch pad button pushing the pump button 4 times cycles its operation
through 4 modes Automatic, Manual Low Speed, Manual High Speed and Standby. When the spa is running
in automatic mode, pressing the pump 1 button will deactivate auto mode and set the pump running in
Manual low speed. The auto LED is orange when auto mode is enabled and off when in manual low speed
or manual high speed. When the pump is in standby mode all indicator LED’s are off.
Push 1 (Manual Low Speed)
Push 2 (Manual High Speed)
Push 3 (Standby Mode)
Push 4 (Auto Mode)
Notes:
1) If Pump 1 is left in ”Manual or “Standby” modes, it will automatically revert to “Auto” mode after 90 minutes.
2) There is no direct user control over the heater. The heater may come on automatically whenever Pump 1 is on.
3) If the heater element is on, running the pump in high speed may cause the heater to load shed and switch off.
3.4 Pump 1 (Two speed, 24HR circulation pump fitted)
Pushing the pump button three times cycles the pump through its two speeds then off. The pump LED is
green when the pump is running in low or high speed and off when pump is off.
Push 1 (Low Speed)
Push 2 (High Speed)
Push 3 (Pump off)
Notes:
1) If Pump 1 is left on, it will automatically switch off after 20 minutes.
2) There is no direct user control over the heater. The heater may come on automatically whenever the 24hr
circulation pump is on.
3) If the heater element is on, running the pump in high speed may cause the heater to load shed
and switch off. If this occurs the heater will come back on approximately 5 seconds after the pump is
deselected.
4. AUXILIARY AIR BUTTON
The Air Button controls anauxiliary air blower. It is used to turn the blower on and off, and select different
operating modes if a Spa Power Variable-Speed Blower (SPVSB) has been fitted. 2 pushes (STD) or 4
pushes (SPVSB) of the air button cycles the blower as follows: Note:In some spas an additional jet pump or
pool light etc may be fitted instead of a standard air blower.
Standard Air Blower (STD)
Push 1 - Blower ON
Push 2 - Blower OFF
Spa Power Variable-Speed Blower (SPVSB) (if fitted)