8. SELF-DIAGNOSTIC ERROR CODES
The Spa Power controller has extensive self diagnostic capabilities. In the event of a problem it will indicate
an error number according to the nature of the problem. The error numbers and their meanings are listed
below.
Note:When in an error state the alarm can be muted by pushing the AIR/AUX button.
Error 1 (H20) - Prime Failed
This is not necessarily a problem with the controller itself, but indicates that no water is being detected in the
heater housing. Prime failed is a special case in that it can be recovered from by pushing a button.A push
of the pump button will run the pump for 10 seconds to try to get water to the heater.If successful normal
operation will resume.If unsuccessful, Error 1(H20) will be indicated on the display again.
With any Error
3-8, spa operation will stop and not continue until the controller is reset. The controller can only be
reset by pushing the UP, DOWN and PUMP buttons simultaneously.
The controller will remain in an error
condition even when reset at mains power, controller will only continue normal operation after the UP, DOWN
and PUMP buttons are pushed simultaneously (see below).
Error 3 - Stuck Button
This error indicates that one of the buttons in the touchpad is stuck or has been held down for more than one
minute.
This may be caused by the pool cover pressing on the touchpad or by water getting into the touchpad or by
damage to the touchpad or its cable. Try to reset the spa. If there is still a problem then contact your spa pool
supplier.
Error 4 - No Water Sensor
This error indicates a problem with the optical water sensor in the heater. The problem may by caused by the
sensor being disconnected or by damage to the sensor. Try to reset the spa. If there is still a problem then
contact your spa pool supplier.
Error 5 - Overtemperature
This error indicates that the digital temperature sensor in the heater or pool has detected a temperature of
45
o
C or more.This may not be a problem with the controller, it may be caused by excessive pump use in hot
weather, or pump failure. Turn off the spa and allow time for the water to cool. If there is still a problem then
contact your spa pool supplier.
Error 6 - Thermal Cut Out Tripped
This error indicates that the safety electromechanical over temperature cut out on the heater has operated.
This is not necessarily a problem with the controller. It may have occurred from an air lock around the
element, high temperatures during shipping, or failure of the pump. This automatic cut out will only reset
once the element has cooled below about 38 C. The unit must then be reset before it will resume operation.
Manually push the UP, DOWN and PUMP buttons simultaneously.
Error 7- Stuck Relay
This error indicates a problem with the heater control circuitry inside the unit. Contact your spa pool supplier.
Error 8 - No Temperature Data
This error indicates a problem with the digital temperature sensor in the heater or pool wall or that both the
in heater and in pool sensors are connected. Check that only one sensor is connected and that it has not
become disconnected or damaged. Try to reset the spa. If there is still a problem then contact your spa pool
supplier.