Ambient conditions
Operating temperature range
0 °C - +60 °C (-20 °C - +60 °C on request)
Storage temperature range
-25 °C - +70 °C
Climatic conditions:
EN 60654-1, class B2
Relative humidity:
90% (max., non-condensing)
Place of installation: Cabinet
Electromagnetic compatibility (EMC)
In accordance with the standard EN 61326-1:2006
Emission:
Conducted: EN
55011:1998
Limits for Class A equipments
Radiated: EN
55011:1998
Limits for Class A equipments
Immunity:
ESD:
4 kV/8 kV contact / air
-B- criteria
BURST:
2 kV/1 kV power / signal
-B- criteria
SURGE: 1
kV
-B-
criteria
Conducted RF:
3 Veff
-A- criteria
General data
Housing: TS-35
rail
mounting
housing
material: polyamide PA6.6
Dimensions [mm]:
screw-terminal
Panel cut off:
2.5 mm
2
(max.)
Weight:
45 x 99 x 115 mm (width x height x depth)
Protection: IP
20