Error messages
Low
(
E
rror:
LOW
Input signal)
Reason of error: the input signal is under of the measuring
range. For example: the selected input mode is 4-20 mA
and the input signal is 0 mA.
A/D underflow
(
E
rror:
AD
Un
derflow)
Reason of error: input signal is under of the measuring
range.
A/D overflow
(
E
rror:
A/D
O
verflow)
Reason of error: input signal is over of the measuring range.
Display under
(
Underf
low)
Reason of error: value to be displayed is < -9999.
Display overflow
(
Overf
low)
Reason of error: value to be displayed is > 99999.
Missing Minimum-maximum values
(
E
rror: Missing
Mi
nimum-
Ma
ximum)
Saving the last settings was not successful
(
E
rror:
Save
)
Scaling error
(
Scale
)
Reason of error: the given physical value is not correct.
Messages of critical
errors
In case of a critical error call manufacturer sertvice
department!
A/D converter error
(
S
ervice:
ADC
)
EEPROM error
(
S
ervice:
EEPR
OM)
Calibration error
(
S
ervice:
Cal
ibration)
Factory calibration is damaged.
Analogue output calibration error
(
S
ervice:
A
nalog
Cal
ibration)
Factory calibration is damaged.
Factory settings
(
S
ervice:
Fact
ory Settings)
Data stored in EEPROM are damaged (factory calibration
also).
Summary of Contents for DT1400 RL2 IA
Page 1: ...DT1400 xx xx Limit switch Operating Instructions ...
Page 68: ...DT1400 xx xx 68 20170920 V0 10 2 Application example Analog output option ...
Page 69: ...DT1400 xx xx 20170920 V0 69 RL4 option ...
Page 70: ...DT1400 xx xx 70 20170920 V0 TS option ...
Page 71: ...DT1400 xx xx 20170920 V0 71 ...
Page 72: ......