11
Chapter 3 Network Setup
3.1 Initial SE-1200 MU Setup with a Windows Computer
The SE-1200 MU switcher is not supplied with a traditional hardware based control panel. Instead it is
controlled using a software user interface installed on your Windows-based computer.
When new from
the factory the unit will initially have a static IP address of 192.168.100.101.
The unit can be directly
connected to a Windows-based computer using an RJ-45 ethernet cable. The following set up should allow
you to initially configure the unit before moving it to an existing DHCP / LAN network.
•
An RJ-45 ethernet cable.
•
Windows 7/8 laptop or PC.
•
The Datavideo SE-1200 MU controller
software.
Instructions
1.
First connect the SE-1200 MU and the Windows computer together using an RJ-45 ethernet cable.
2.
Turn on the Windows computer and set it to
static IP set up
within the
Windows Network and
Sharing Centre
.
In our example the computer is given the following IP settings so that the computer matches the
same IP range as the switcher.
3.
Now install the supplied SE-1200 MU controller software to the computer.